560 – Mixture throttle B
Red alarm. Engine shutdown.
Associated parameter 1.1450.013
Cause
Corrective action
A problem related to mixture
throttle on B side occurred.
Possible causes: Mixture throttle
defective, no power supply to
throttle, cabling of feedback
and/or position signal faulty.
u
Check mixture throttle on B side and cabling. Replace mixture
throttle on B side as necessary.
565 – AL L1 P-Intake Air after Filter A
Yellow alarm.
Associated parameter 2.0186.921
Cause
Corrective action
Pressure loss over air filter on A
side is too high.
u
Replace air filter (→ Page 151).
566 – AL L2 P-Intake Air after Filter A
Yellow alarm.
Associated parameter 2.0186.931
Cause
Corrective action
Pressure loss over air filter on A
side is too high.
u
Replace air filter (→ Page 151).
567 – AL L1 P-Intake Air after Filter B
Yellow alarm.
Associated parameter 2.0187.921
Cause
Corrective action
Pressure loss over air filter on B
side is too high.
u
Replace air filter (→ Page 151).
568 – AL L2 P-Intake Air after Filter B
Yellow alarm.
Associated parameter 2.0187.931
Cause
Corrective action
Pressure loss over air filter on B
side is too high.
u
Replace air filter (→ Page 151).