6.7.2 Engine oil – Change
Preconditions
☑
Engine is stopped and starting disabled.
☑
Engine is at operating temperature.
☑
MTU Fluids and Lubricants Specifications (A001061/..) are available.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Engine oil
WARNING
Hot oil.
Oil can contain combustion residues which are harmful to health.
Risk of injury and poisoning!
• Wear protective clothing, gloves, and goggles / safety mask.
• Avoid contact with skin.
• Do not inhale oil vapor.
WARNING
Oils/oil vapors are combustible/explosive.
Risk of fire and explosion!
• Avoid open flames, electric sparks and ignition sources.
• Do not smoke.
Engine oil extraction
1.
Open shut-off valve(s) in extraction line on engine and waste-oil tank.
2.
Extract all oil from oil pan using the electric pump.
3.
Close shut-off valve(s).
Filling with new engine oil
1.
Determine oil change quantity for fuel optimized (→ Page 24) or emissions-optimized (→ Page 28) en-
gine version.
2.
Use electric pump to fill engine with oil from new-oil tank until the "max." mark on the oil dipstick is
reached.
3.
Check engine oil level (→ Page 174).
MS15027/02E 2015-04
| Task Description | 175
TIM-ID: 0000029137 - 002