Exchanging spark plug isolator
sealing ring
1.
Insert screwdriver (3) between Teflon
sleeve (1) and sealing ring (2).
2.
Pry out and pull out sealing ring (2).
3.
Fold together new sealing ring (2).
4.
Insert sealing ring (2) into the bore in Tef-
lon sleeve (1) with the article number fac-
ing downwards.
5.
Carefully press sealing ring (1) into the
groove until it is flush with the bore in Tef-
lon sleeve (2).
MS15027/02E 2015-04