
Monitoring in engine room
Engine control and monitoring unit (Local Operation Panel, LOP)
Functions:
• Alphanumeric, monochrome LCD display for monitoring of measured values as well as alarms when limits
are violated;
• Pushbuttons for menu control and dimming unit;
• Combined control and display elements for local engine/gear control;
• Flashing lamp and horn for summary alarm in engine room;
• Interface to CAN field bus for connected, communicating monitoring system components
SOLAS – Fire safety specifications
The following figures show all lines with SOLAS-compliant covers for pipe connections according to MTU
standard MTN 5233.
Fuel system, fuel lines with fuel pressure >1.8 bar
1 Fuel line to fuel filter head
1 Fuel line from/to fuel filter head
36 | General Information | MS150045/03E 2018-08
TIM-ID: 0000010056 - 006
Summary of Contents for 12V4000M73 series
Page 1: ...Operating Instructions Diesel engine 12V4000M73x 16V4000M73x MS150045 03E...
Page 3: ......
Page 4: ......