361 – AL Power Stage Low
ZKP-Number: 1.8004.496
Cause
Corrective action
Internal electronic fault
(electronics possibly faulty). If bit
"1.1020.021" (Power Stage
Failure: Stop Engine) is set,
engine will be shut down as
additional measure.
u
Start ITS. If the ITS diagnosis result is "electronics OK", note
further fault messages (e.g. cabling faults).
362 – AL Power Stage High
ZKP-Number: 1.8004.497
Cause
Corrective action
Internal electronic fault
(electronics possibly faulty). If bit
"1.1020.021" (Power Stage
Failure: Stop Engine) is set,
engine will be shut down as
additional measure.
u
Start ITS. If the ITS diagnosis result is "electronics OK", note
further fault messages (e.g. cabling faults).
363 – AL Stop Power Stage
ZKP-Number: 1.8004.560
Cause
Corrective action
Internal electronic fault
(electronics possibly faulty). If bit
"1.1020.021" (Power Stage
Failure: Stop Engine) is set,
engine will be shut down as
additional measure.
u
Start ITS. If the ITS diagnosis result is "electronics OK", note
further fault messages (e.g. cabling faults).
365 – AL Stop MV-Wiring Ground
ZKP-Number: 1.8004.561
Cause
Corrective action
Injector cabling fault. If bit
"1.1020.021" (Power Stage
Failure: Stop Engine) is set,
engine will be shut down as
additional measure. Possible
causes:
1. Short circuit of positive
connection of one or more
injectors to ground
2. Short circuit of negative
connection of one or more
injectors to ground.
u
Check wiring, replace wiring harness as necessary.
MS150045/03E 2018-08