4.3 Putting the engine into operation after scheduled out-of-
service-period
Preconditions
☑
Engine is stopped and starting disabled.
Putting into operation
Item
Action
Lube oil system
Check engine oil level (→ Page 214);
Preheat engine oil if required.
Coolant circuit
Check coolant level (→ Page 228).
Coolant circuit
Heat coolant with coolant preheating unit.
Engine control system
Switch master switch to ON;
Press illuminated pushbutton READY FOR OPERATION (→ Page 99).
LOP
Press illuminated pushbutton LAMP TEST (→ Page 99).
ECU
Check plug connections (→ Page 249).
EIM
Check plug connections (→ Page 251).
EMU 8
Check plug connections (→ Page 250).
MS150045/03E 2018-08