601 – SD ETC1+ETC2
ZKP-Number: 1.3011.227
Cause
Corrective action
SD ETC1 and ETC2
u
Check sensor and cabling, replace as necessary.
625 – SD P-Fuel before Prefilter
ZKP-Number: 1.8004.600
Cause
Corrective action
Analog input signal for pressure
before prefilter faulty; Short
circuit or wire break
1. Check pressure sensor and cabling, replace as necessary.
2. Error cleared after restarting the engine.