1062 – AL Inj. Drift Limit 2 Cyl. B1
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B1 has violated limit 2.
The injector has reached its
maximum drift limit.
u
Replace injector (→ Page 134).
1063 – AL Inj. Drift Limit 2 Cyl. B2
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B2 has violated limit 2.
The injector has reached its
maximum drift limit.
u
Replace injector (→ Page 134).
1064 – AL Inj. Drift Limit 2 Cyl. B3
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B3 has violated limit 2.
The injector has reached its
maximum drift limit.
u
Replace injector (→ Page 134).
1065 – AL Inj. Drift Limit 2 Cyl. B4
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B4 has violated limit 2.
The injector has reached its
maximum drift limit.
u
Replace injector (→ Page 134).
1066 – AL Inj. Drift Limit 2 Cyl. B5
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B5 has violated limit 2.
The injector has reached its
maximum drift limit.
u
Replace injector (→ Page 134).
1067 – AL Inj. Drift Limit 2 Cyl. B6
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B6 has violated limit 2.
The injector has reached its
maximum drift limit.
u
Replace injector (→ Page 134).
108 | Troubleshooting | MS15060/01E 2018-12
TIM-ID: 0000068683 - 006