1038 – AL Inj. Drift Limit 1 Cyl. A7
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector A7 has violated limit 1.
The injector has soon reached its
maximum drift limit.
u
Schedule an injector replacement.
1039 – AL Inj. Drift Limit 1 Cyl. A8
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector A8 has violated limit 1.
The injector has soon reached its
maximum drift limit.
u
Schedule an injector replacement.
1040 – AL Inj. Drift Limit 1 Cyl. A9
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector A9 has violated limit 1.
The injector has soon reached its
maximum drift limit.
u
Schedule an injector replacement.
1041 – AL Inj. Drift Limit 1 Cyl. A10
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector A10 has violated limit
1. The injector has soon reached
its maximum drift limit.
u
Schedule an injector replacement.
1042 – AL Inj. Drift Limit 1 Cyl. B1
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B1 has violated limit 1.
The injector has soon reached its
maximum drift limit.
u
Schedule an injector replacement.
1043 – AL Inj. Drift Limit 1 Cyl. B2
Cause
Corrective action
The drift correction for
energization (start and duration)
of injector B2 has violated limit 1.
The injector has soon reached its
maximum drift limit.
u
Schedule an injector replacement.
104 | Troubleshooting | MS15060/01E 2018-12
TIM-ID: 0000068683 - 006