1.4520.249 – Open Primary, Channel 5
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.250 – Open Primary, Channel 6
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.251 – Open Primary, Channel 7
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.252 – Open Primary, Channel 8
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.253 – Open Primary, Channel 9
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.254 – Open Primary, Channel 10
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
1.4520.255 – Open Primary, Channel 11
Yellow alarm. Initiated by IC922.
Cause
Corrective action
Ignition energy was not
discharged.
1. Check cabling to ignition coil.
2. Check ignition coils.
78 | Troubleshooting | MS150108/02E 2015-03
TIM-ID: 0000038611 - 002