Number of cylinders
20
Gas type: Natural gas
X
Methane number, min.
L
80
Table 6: General conditions (for maximum power)
Consumption
Number of cylinders
20
Lube oil consumption after 1000 h runtime
g/kWh
0.2
Table 7: Consumption
Model related data (basic design)
Number of cylinders
20
Operating method: Four-stroke cycle, Otto engine, single-acting
X
Combustion method: Mixture charging, spark ignition
X
Number of cylinders
20
Cylinder arrangement: V angle
Degrees
(°)
90
Bore
mm
170
Stroke
mm
210
Cylinder displacement
Liters
4.77
Total displacement
Liters
95.33
Compression ratio
12.8
Standard housing connecting flange (engine main PTO)
SAE
00
Table 8: Model related data (basic design)
Coolant system (HT circuit)
Number of cylinders
20
Coolant temperature (at engine connection: outlet to cooling equipment) (w/o
antifreeze)
A
°C
90
Coolant temperature (at engine connection: inlet from cooling equipment)
(w/o antifreeze)
A
°C
78
Coolant temperature after engine, warning
R
°C
95
Coolant temperature after engine, shutdown
L
°C
98
Coolant temperature to enable load application, min.
L
°C
40
Coolant antifreeze content, max.
L
%
50
Coolant pump: Volumetric flow
L
m³/h
87
Filling pressure in cooling system (cold)
R
bar
0.5
Pressure in cooling system, max.
L
bar
6.0
Pressure loss over engine (at nominal flow rate 7.27)
bar
2.3
Thermostat: Starts to open
R
°C
68
Thermostat: Opening stops (thermostat fully open and bypass closed)
A
°C
78
Table 9: Coolant system (HT circuit)
MS150108/02E 2015-03
| Product Summary | 25
TIM-ID: 0000044014 - 002