7.19 Battery-Charging Generator
7.19.1 Battery-charging generator drive – Drive belt check and adjustment
Preconditions
☑ Engine is stopped and starting disabled.
Special tools, Material, Spare parts
Designation / Use
Part No.
Qty.
Assembly device
F6559691
1
Preparatory steps
1.
Remove limit switch (4).
2.
Remove indicator (1).
3.
Remove screws (3) of protective cover (2).
4.
Remove protective cover.
5.
Check drive belt condition (→ Page 228).
Belt drive – Checking distance
1.
Measure distance (A) with assembly de‐
vice.
2.
If measured value of distance (A) is not
within the tolerance of 98 mm ± 1.5 mm, re‐
adjust belt tension.
MW15550/06E 2012-02 | Task Description | 229