Maintenance
64
Series 505G2 SilentFlo™ Hydraulic Power Unit
Model 505.07 HPU Top View
9. Turn on the HPU and switch to high-pressure mode. Inspect the seal between the housing
and the manifold for any signs of leakage. If leakage occurs, repeat this procedure (without
replacing the filter element). If leakage persists, contact MTS Systems Corporation.
10. If you are changing the filter because the dirty filter indicator tripped, run the HPU for two to
four hours to remove contaminants. Then take a fluid sample and have it analyzed.
Continue to clean the fluid if it does not meet an ISO cleanliness level of 13/9 or better.
11. Press the Reset button on the HPU control panel to reset any interlocks and turn off the Dirty
Filter indicator.
Sample the Hydraulic Fluid
This section describes how to check the quality of the hydraulic fluid. Review the following hints before
obtaining your sample:
l
Avoid contamination.
l
Keep the sample bottle in the storage box of the hydraulic fluid sampling kit until it is
needed.
l
Do not remove the cap from the bottle until immediately before taking the sample.
l
Do not set the cap down on a dirty surface or in an area where airborne dust can
settle.
l
For additional information on hydraulic fluid care, see the Hydraulic Fluid Care Guide (part
number 050-000-536) found in the documentation package inside the electrical control box.
Summary of Contents for SilentFlo 505G2 Series
Page 1: ...Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2 07 Model 505G2 11 100 227 350 C ...
Page 39: ...Operation Series 505G2 SilentFlo Hydraulic Power Unit 39 Operation Operator s Panel 40 ...
Page 70: ......
Page 79: ...Accessories Series 505G2 SilentFlo Hydraulic Power Unit 79 Caster Kit ...
Page 80: ......
Page 90: ...Appendix B Declaration of Conformity 90 Series 505G2 SilentFlo Hydraulic Power Unit Example ...
Page 91: ...Appendix B Declaration of Conformity Series 505G2 SilentFlo Hydraulic Power Unit 91 ...
Page 92: ......
Page 93: ......