Operation
Series 505G2 SilentFlo™ Hydraulic Power Unit
45
Name and Location
Description
Motor Overload- red: Indicates the pump motor has overheated
and an interlock is active.
Motor Sequence
OK/Motor Sequence
Fault
Indicator. Used to indicate if the pump motor sequence is operating
properly.
Motor Sequence OK - gray: Indicates the motor sequence is not in
a fault condition and operating properly.
Motor Sequence Fault- red: Indicates that the PLC commanded the
motor contactor to close but the contactor did not close after a 10
second time period.
Return Filter
OK/Return Filter Fault
Indicator. Used to indicate if the return filter is within acceptable
limits.
Return Filter OK - gray: Indicates the contamination in the return
filter is within acceptable limits.
Return Filter Dirty - yellow: Indicates the contamination in the return
filter is not within acceptable limits. This state will not generate an
active interlock, but alerts the user that the filter requires
maintenance.
The HPU cannot be started with an active return filter warning
Pressure Filter
OK/Pressure Filter
Fault
Part of the Pressure
Filter Option; only
displayed if the
Pressure filter Option
was purchased.
Indicator. Used to indicate if the pressure filter is within acceptable
limits.
Press Filter OK - gray: Indicates the contamination in the pressure
filter is within acceptable limits.
Press Filter Dirt y- yellow: Indicates the contamination in the
pressure filter is not within acceptable limits. This state will not
generate an active interlock, but alerts the user that the filter
requires maintenance.
The HPU cannot be started with an active pressure filter warning.
Screen select buttons
These pushbutton/indicators are described in the Main Screen
section; refer to
Operating the HPU Locally or Remotely
The HPU can be operated locally using the controls on the user interface panel or remotely using your
system controller.
Summary of Contents for SilentFlo 505G2 Series
Page 1: ...Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2 07 Model 505G2 11 100 227 350 C ...
Page 39: ...Operation Series 505G2 SilentFlo Hydraulic Power Unit 39 Operation Operator s Panel 40 ...
Page 70: ......
Page 79: ...Accessories Series 505G2 SilentFlo Hydraulic Power Unit 79 Caster Kit ...
Page 80: ......
Page 90: ...Appendix B Declaration of Conformity 90 Series 505G2 SilentFlo Hydraulic Power Unit Example ...
Page 91: ...Appendix B Declaration of Conformity Series 505G2 SilentFlo Hydraulic Power Unit 91 ...
Page 92: ......
Page 93: ......