Temposonics
®
R-Series
V
SSI
Operation Manual
I 16 I
Start- and end positions of the position magnets
Consider the start and end positions of the position magnets during
the installation. To ensure that the entire stroke length is electrical-
ly usable, the position magnet must be mechanically mounted as fol-
lows.
Fig. 17: Start- & end positions of magnets for RP5
Fig. 18: Start- & end positions of magnets for RH5
Controlling design dimensions are in millimeters and measurements in ( ) are in inches
NOTICE
On all sensors, the areas left and right of the active stroke length are
provided for null and dead zone. These zones should not be used for
measurement, however the active stroke length can be exceeded.
RP5 with magnet slider “S”, “N”, “V”, “G”
Sensor electronics housing
Reference edge of mounting
Start position
12 (0.47)
End position
82/87* (3.23/3.43*)
* Stroke length > 5000 mm (196.9 in.)
RP5 with U-magnet
Reference edge of mounting
Sensor electronics housing
Start position
28 (1.1)
End position
66/71* (2.6/2.8*)
* Stroke length > 5000 mm (196.9 in.)
RP5 with block magnet
Reference edge of mounting
Sensor electronics housing
* Stroke length > 5000 mm (196.9 in.)
End position
68.5/73.5* (2.7/2.9*)
Start position
25.5 (1)
RH5 with ring magnet/U-magnet
Sensor electronics housing
Reference edge of mounting
Start position
51 (2.01)
End position
63.5/66* (2.5/2.6*)
* Stroke length > 5000 mm (196.9 in.)
RH5 with block magnet
Sensor electronics housing
Reference edge of mounting
Start position
48.5 (1.91)
End position
66/68.5* (2.6/2.7*)
* Stroke length > 5000 mm (196.9 in.)
RP5 with magnet slider “S”, “N”, “V”, “G”
Sensor electronics housing
Reference edge of mounting
Start position
12 (0.47)
End position
82/87* (3.23/3.43*)
* Stroke length > 5000 mm (196.9 in.)
RP5 with U-magnet
Reference edge of mounting
Sensor electronics housing
Start position
28 (1.1)
End position
66/71* (2.6/2.8*)
* Stroke length > 5000 mm (196.9 in.)
RP5 with block magnet
Reference edge of mounting
Sensor electronics housing
* Stroke length > 5000 mm (196.9 in.)
End position
68.5/73.5* (2.7/2.9*)
Start position
25.5 (1)
RH5 with ring magnet/U-magnet
Sensor electronics housing
Reference edge of mounting
Start position
51 (2.01)
End position
63.5/66* (2.5/2.6*)
* Stroke length > 5000 mm (196.9 in.)
RH5 with block magnet
Sensor electronics housing
Reference edge of mounting
Start position
48.5 (1.91)
End position
66/68.5* (2.6/2.7*)
* Stroke length > 5000 mm (196.9 in.)
Differential measurement
For a differential measurement two positions are measured on the
sensor rod or sensor profile. The distance between these positions will
be output.
RP5 with U-magnets
≥ 75 (≥ 3)
RP5 with magnet sliders
≥ 75 (≥ 3)
RP5 with block magnets
≥ 75 (≥ 3)
RH5 with ring magnets/U-magnets
≥ 75 (≥ 3)
RH5 with block magnets
≥ 75 (≥ 3)
Fig. 19: Minimum distance between magnets for differential measurement
NOTICE
Do not go below a minimal distance of 75 mm (3 in.) between
the magnets for differential measurement
3
. Use magnets of the
same type (e.g. 2 × U-magnet, part no. 251 416-2) for differential
measurement.
3/
Contact MTS Sensors if you need a magnet distance, which is smaller than 75 mm (3 in.).