Temposonics
®
R-Series
V
SSI
Operation Manual
I 13 I
Controlling design dimensions are in millimeters and measurements in ( ) are in inches
Fig. 7: Temposonics
®
RH5 with ring magnet, part 2
RH5-J-A/-V – RH5 with threaded flange M22×1.5-6g and Ø 12.7 mm rod, example: Connection type D70 (connector output)
25
(0.98)
A/F 46
53
(2.09)
Sensor electronics housing
68
(2.68)
Null zone
51
(2.01)
Stroke length
25…5900
(1…232)
Threaded flange
»J«
:
M22×1.5-6g
Magnet
Ø 12.7
±0.
13
(Ø
0.5
±0.
01
)
Dead zone
73.6
(2.9)
11.7
(0.46)
RH5-B-A/-V – RH5 base unit (only for replacement), example: Connection type D70 (connector output)
48
(1.89)
Sensor electronics
housing
58
(2.28)
Null zone
61
(2.4)
Stroke length
25…7620
(1…300)
Dead zone
52/54/57**
(2.05/2.13/2.24)**
** Stroke length 25…1575 (1…62): 52 (2.05) dead zone
Stroke length 1576…5000 (62.05…196.9): 54 (2.13) dead zone
Stroke length 5001…7620 (196.9…300): 57 (2.24) dead zone
11.7
(0.46)