background image

Temposonics

®

Magnetostrictive Linear Position Sensors

ET  Analog  ATEX  /  IECEx  /  CEC  /  NEC  /  CCC  Certified

Operation Manual 

Summary of Contents for Temposonics E Series

Page 1: ...Temposonics Magnetostrictive Linear Position Sensors ET Analog ATEX IECEx CEC NEC CCC Certified Operation Manual...

Page 2: ...le 8 4 3 Styles and installation of Temposonics ET profile style 10 4 4 Magnet installation 11 4 5 Electrical connection 12 4 6 Frequently ordered accessories for ET F W M S 14 4 7 Frequently ordered...

Page 3: ...g a PLC IPC indicator or other electron ic control unit 2 The sensor s surface temperature class is T4 3 The ATEX IECEx CEC NEC and CCC certificates have to be taken into account including any specia...

Page 4: ...sensor via the ground lug Both the sensor and the moving magnet including magnet holder must be connect ed to protective ground PE to avoid electrostatic discharge ESD 11 Before applying power ensure...

Page 5: ...lication 2 The MTS Sensors obligation is limited to repair or replacement of any defective part of the unit No warranty can be provided for defects that are due to improper use or above average stress...

Page 6: ...o 530 112 T01 T30 1 30 m 3 99 ft See Frequently ordered accessories for cable speci cations V X X XX m silicone cable part no 530 113 V01 V30 1 30 m 3 99 ft See Frequently ordered accessories for cabl...

Page 7: ...ted into an electrical signal Since the speed of the ultrasonic wave in the waveguide is precisely known the time required to receive the return signal can be converted into a linear position measurem...

Page 8: ...of the hydraulic fluid The pressure resistant sensor rod is installed into a bore in the piston rod Fig 6 Sensor in cylinder Fastening torque 75 Nm Position magnet ET F M S W example Version A N Thre...

Page 9: ...er gasket O ring etc The position magnet should not grind on the sensor rod The piston rod drilling 13 mm 0 51 in depends on the pressure and piston speed Adhere to the information relating to operati...

Page 10: ...es For fastening we recommend using M5 20 screws DIN 6912 that should be tightened with a fastening torque of 5 Nm Fastening torque 5 Nm 50 1 97 9 5 0 37 Bore 5 3 0 21 14 6 0 57 Fig 10 Mounting clamps...

Page 11: ...can be lifted off Magnet sliders Pro le models ET P The magnet is guided by the pro le The distance between the magnet and the waveguide is strictly de ned Easy coupling via the ball joint Rod sensors...

Page 12: ...e from power cables and sufficiently far away from motor cables frequency inverters valve lines relays etc Use only connectors with metal housing if you use a connector Connect the shielding to the co...

Page 13: ...C approval via ground lug as shown in Fig 20 Connector wiring Connect the sensor directly to the controller indicator or other evaluating systems as follows TXX VXX Signal power supply Cable Color Vol...

Page 14: ...1 25 4 3 0 17 3 2 0 13 15 3 0 6 2 2 0 09 U magnet OD63 5 Part no 201 553 Block magnet L Part no 403 448 Magnet spacer Part no 400 633 O ring for threaded ange M18 1 5 6g Part no 401 133 Material PA 66...

Page 15: ...Material GRP magnet hard ferrite Weight Approx 25 g Operating temperature 40 85 C 40 185 F Position magnets Mounting accessories 32 8 1 29 23 8 0 94 13 5 0 53 4 3 0 17 60 140 3 0 12 7 9 0 31 19 5 0 77...

Page 16: ...onments Hand programmer for analog output Part no 253 124 Programming kit Part no 254 555 Cabinet programmer for analog output Part no 253 408 Easy teach in setups of stroke length and direction on de...

Page 17: ...as well as the measuring direction via simple teach in process see also 5 2 4 Setting examples for pro gramming tools on page 23 After that the changed parameters are stored in the sensor Move the po...

Page 18: ...start and end position 3 Set end position 100 output Fig 267 Set the position magnet on end position Press and release the 100 button 4 Back to normal function operation mode Press Start button Connec...

Page 19: ...ct cabinet programmer Step 3 Adjust measuring range Fig 28 Dimensions 10 55 31 mm 0 39 2 17 1 22 in material Aluminum side caps PA 6 6 FR connection type Spring terminals max 1 5 mm 2 ingress protecti...

Page 20: ...ogramming mode stops flashing Slide switch to Run Green LED 24 VDC shows normal function Output 1 Output 2 Output from order code Start posi tion 0 output End positi on 100 output Start posi tion 0 ou...

Page 21: ...rammer to a USB port of the computer Connect the power supply via connector The outer contact of the connector is 0 V ground the inner contact is 24 VDC NOTICE Never connect disconnect the sensor when...

Page 22: ...Fig 33 Status indicates that the sensor is connected successfully Fig 33 Dialog field with tabs Determine the measuring range with Startpoint and Endpoint via tab Function 1 Fig 34 The current magnet...

Page 23: ...SP1 set point 1 at sensor electronics housing and SP2 set point 2 at rod end Fig 37 Fig 38 Fig 37 Adjust start and end position Fig 38 Start and end position adjustment reversal of measuring directio...

Page 24: ...ut without dismantling or if necessary with partial dismantling and supplemented by other measures e g measurements Visual inspection Optical inspection of product aims at the recognition of visible d...

Page 25: ...nly for rod version Up to 350 bar 5076 psi Magnet movement velocity 7 Any Design Material Sensor electronics housing Flange Stainless steel 1 4305 AISI 303 option Stainless steel 1 4404 AISI 316L Sens...

Page 26: ...on Manual Fig 41 Certification of Temposonics ET version A and E Certification II 3G Ex nC IIC T4 Gc Ex tD A21 IP66 IP68 T130 C II 3D Ex tc IIIC T130 C Dc IP66 IP68 Class I II III Div 2 T4 ABCDFG Clas...

Page 27: ...ne or several sensors for checking or repair we need you to sign a safety declaration The purpose of this declaration is to ensure that the returned items do not contain residues of harmful substances...

Page 28: ...2011 65 EU Restriction of the use of hazardous substances in electrical and electronic equipment Beschr nkung der Verwendung gef hrlicher Stoffe in Elektro und Elektronikger ten Limitation de l utilis...

Page 29: ...es capteurs position de type Temposonics ET x xxxxx Txx 1 N aaa aaa V01 V02 V03 V11 V12 ET x xxxxx Vxx 1 N aaa A01 A02 A03 A11 A12 ET x xxxxx Txx 1 N Sxxxxxx ET x xxxxx Vxx 1 N Sxxxxxx comply with the...

Page 30: ...ormation Applicable Standards CSA C22 2 No 60079 0 2015 CSA C22 2 No 60079 15 2016 CSA C22 2 No 60079 31 2015 CSA C22 2 No 61010 1 2012 CSA C22 2 94 2 2015 ANSI ISA 12 12 01 2015 ANSI UL 61010 1 2012...

Page 31: ...85 C Type 4X Digital Start Stop Ex nC IIC T4 Gc Ex tc IIIC T130 C Dc IP66 68 40 C Ta 105 C Type 4X Class I II III Div 2 T4 ABCDFG Class I Zone 2 T4 IIC Zone 22 AEx tc T4 IIIC Dc 40 C Ta 105 C Type 4X...

Page 32: ......

Page 33: ...com JAPAN Branch Of ce Phone 81 3 6416 1063 E mail info jp mtssensors com www mtssensors com MTS Temposonics and Level Plus are registered trademarks of MTS Systems Corporation in the United States M...