MTH GP38-2 Operating Instructions

BATTERY PROBLEMS

REMEDY

I get no sounds when the engine shifts between the
direction states.

The battery may be dead or needs charging.  See the
Battery Backup section for more information.

After I turn off my transformer, my engine continues to
make sounds before quitting with a ding of its bell.

ProtoSounds continues to sound for approximately 10
seconds after power to the track has been shut off.

The sounds distort at low voltages.

The battery is insufficiently charged or dead.  Follow
the recharging instructions found in the section entitled 
“Self Recharging Battery Backup System”.

A repeating horn blast occurs after the power has
been shut down.

The ProtoSound module has detected a problem with
the electronics.  Should such a warning occur,
disconnect the battery and contact MTH for return
authorization instructions.

RESET PROBLEMS

REMEDY

When I first turn the power on, the engine will not
begin to run.  I have to turn the throttle off and then on
again to get the engine to operate.

This is normal behavior.  When power to the track is
first turned on, ProtoSounds enters a “RESET” phase
at which time the engine undergoes a system check.
Power must be interrupted to get the engine into the
Forward Phase.  See the section entitled “DCRU
Reverse Unit Operation” for more information.

Whenever I interrupt the power from RESET to enter
Forward, the engine goes back into RESET instead of
Forward.  I know this occurs because the bell dings
twice.

Whenever ProtoSounds enters RESET after power
has been off for more than 15 seconds, the
microprocessor initiates a system check to determine
that everything is in working order.  This system check
requires 2.2 seconds to complete during which time
the engine will play the diesel startup sounds.  We
recommend that you don’t interrupt the power in
RESET until the diesel startup sounds have
completed.  This will guarantee that the system check
will have been completed since the startup sounds
take longer than 2.2 seconds to play.  If the problem
persists, we recommend that you operate the throttle
with a slower movement as you interrupt the power in
RESET and enter the Forward Phase

BRAKE SOUND PROBLEMS

REMEDY

When the transformer is throttled down, the sounds
won’t play.

The brake features has not been activated.  See the
section on activating the brake feature for more
information.The throttle voltage setting on the
transformer is either not starting high enough or
ending low enough to trigger the brakes sounds.  Try
increasing the throttle setting to 14 volts or higher
before throttling down to 8 volts or less.

The brake sounds continue to play even after the
engine stops.

The brake feature sound record lasts for three
seconds.  With practice you can control how quickly
you should stop the engine to keep it in sequence with
the sound of the brake’s squeaking.

The brake feature was activated in neutral after the
engine was running in forward, but the brake sounds
would not play when triggered after the engine went
back into forward or reverse.

The brake feature will only remain enabled if it is
triggered in the first direction state you enter after
activating the feature in neutral.  You cannot interrupt
the power twice to enter another direction state and
still have the brake feature active.  Therefore, in order
to make the brake sound feature operate in forward,
you must first activate the feature in the neutral
position that occurs after the engine was in the reverse 
state.

After triggering the brake sound and stopping the
engine in neutral, the engine begins making freight
yard sound effects.

After you trigger the brake sounds, you cannot stop
the engine in neutral and leave the track power on
without activating the freight yard sounds.  If you don’t
want to hear the freight yard sounds after entering
neutral, turn the power off for three seconds to disable
the freight yard sound effects.

Summary of Contents for GP38-2 DIESEL ENGINE

Page 1: ...compatible transformers and wiring instructions and is completely compatible with most other 3 rail locomotives rolling stock and accessories The locomotive is equipped with several deluxe features t...

Page 2: ...m 16 Replacing The ProtoSound Battery 16 Manual ProtoSound Volume Adjustment 17 USING RESET TO PROGRAM PROTOSOUNDS 18 Entering RESET Options 18 Remotely Setting The Engine Volume 19 Programming For Sq...

Page 3: ...ormer direction switch if so equipped The reverse unit is designed to ignore dirty track dead spots on switches or minor short circuits without disrupting the engine operation even at slow prototypica...

Page 4: ...o the track the reverse unit begins in RESET or what seems like a neutral state Power must be interrupted again to get the locomotive to enter the forward state It is this first RESET state that gives...

Page 5: ...locomotive using any of these programmable features simply leave RESET and wait 2 2 seconds before interrupting the power to put the engine in forward After you leave RESET your engine will operate n...

Page 6: ...or reverse PROTO COUPLER OPERATION Your GP38 2 ProtoSound equipped locomotive is equipped with two coil wound ProtoCouplers for remote uncoupling action Because the ProtoCoupler is controlled through...

Page 7: ...at random intervals to eliminate repetitive and boring sequences though there is no guarantee that you won t hear the same message repeated two or more times SQUEAKING BRAKE SOUNDS Proto Sound equipp...

Page 8: ...f an engine slowing down for curves crossings or coming to a stop at a station side track or switch yard However you may find that your engine continues to play the brake sounds once your engine comes...

Page 9: ...the Neutral State No additional wires or modifications are needed to enjoy these amazing sound effects The sounds themselves are randomly shuffled by the Proto Sound computer This gives the system the...

Page 10: ...Change Press Direction The Train Will Remain In Neutral It Will Continue to Play More Background Noises d Bell Horn Whistle Direction OR Change Press Direction The Train Will Remain In Neutral You Wi...

Page 11: ...cannot interrupt the power twice to enter another direction and still have the FYS active You can now trigger the sounds to begin playing when you next enter Neutral Option 2 If you do not have a Z 4...

Page 12: ...throttle was at 14 volts or higher the squeaking brakes sound will play Once the engine is stopped the throttle must be turned on to keep it in the neutral state Note Failure to turn the throttle bac...

Page 13: ...the engine will begin moving in forward with the bell continuing to ring A few seconds later the bell will turn off and the engine will resume normal operation Note When entering Event 4 it is importa...

Page 14: ...is equipped with an FYS programmed Proto Sound module If the second engine isn t equipped with FYS the only thing to remember is not to turn up the transformer throttle very high when entering Reverse...

Page 15: ...the throttle OFF then release the horn whistle button After 2 seconds you will hear a short whistle blast IMMEDIATELY turn the throttle back on The engine is now locked and will continue in the previo...

Page 16: ...Proto Sound battery located in the tender body is a special NiCad 7 cell 8 4v battery NOT the 6 cell 7 2v battery found in most convenience stores The battery is continually charged from the track whe...

Page 17: ...ig 4 below allows you to control all the sounds in the system and a remote control RESET option Option 6 allows you to control the volume level of the engine chuff sounds remotely from the transformer...

Page 18: ...vanced In addition there are special sounds to tell you what RESET position you are in For example if you want to select Feature 2 you put the engine in RESET and move the throttle up and down from fu...

Page 19: ...45 allows you to determine if and how the Squeaking Brakes recording will be activated To use cycle to Reset 45 and press the Whistle button The engine will play a series of bells This indicates the c...

Page 20: ...10 2 Clanks Reset 10 allows you to turn the operation of the Proto Coupler on or off When OFF the coupler will not arm or fire from Neutral To use cycle to Reset 10 and press the Whistle button The e...

Page 21: ...et Feature 28 allows you to turn the operation of the FYS sequence on or off When OFF the FYS will not activate To use cycle to Reset 28 and press the Whistle button The engine will play a series of b...

Page 22: ...into forward Resetting All Proto Sound Options To Factory Defaults Reset 18 3 Clanks 3 Clinks Reset 18 is the most powerful of the Reset features available Using Reset 18 allows you to override all c...

Page 23: ...er 50 hours of operation or one year whichever comes first Grease can be added by inserting grease into the gear box inside the locomotive chassis In order to access the gear box the cab must be remov...

Page 24: ...rder to slip the new tire over the grooved drive wheel Figures 5 and 6 identify the screws necessary to remove the body and trucks from the chassis Before the new tire can be installed you must make s...

Page 25: ...nt tires are available directly from MTH Electric Trains HEADLIGHT REPLACEMENT 2 and 3 Rail The locomotive s headlights are controlled by constant voltage circuits inside the locomotive body The headl...

Page 26: ...depressed fully the ProtoSound circuit may not recognize the signal Try pressing the whistle button slower taking approximately 1 second to fully depress the button BELL PROBLEMS REMEDY When I press t...

Page 27: ...he transformer It sits still with the diesel compressor sounds running The engine is locked out into the Neutral position Follow the unlocking procedures in the Lockout Section The engine won t lock o...

Page 28: ...startup sounds have completed This will guarantee that the system check will have been completed since the startup sounds take longer than 2 2 seconds to play If the problem persists we recommend tha...

Page 29: ...t a sound can occasionally be repeated one or more times Once in FYS the engine never goes in reverse So that the freight yard sound effects and operation is as realistic as possible ProtoSounds disab...

Page 30: ...the transformer whistle button until you hear a soft warbled bell sound RESET OPERATION DEFAULT CLANKS CLINKS 6 Engine Volume Full Volume 1 Clank 1 Clinks 10 Coupler ON OFF Coupler ON 2 Clanks 0 Clink...

Page 31: ...t Standard Lionel 1043 U A 5 16v 90 Watt Standard Lionel 1043M U A 5 16v 90 Watt Standard Lionel 1044 U A 5 16v 90 Watt Standard Lionel 1053 U A 8 17v 60 Watt Standard Lionel 1063 U A 8 17v 60 Watt St...

Page 32: ...ollowed including the following Read this and all related manuals transformer power supply locomotive etc thoroughly before using this device This device is not recommended for children under ten year...

Page 33: ...ill blue Fan shroud grill black black blue left P a r t s Name and Number Part 19 Air Horns blue FC 2100251 19 Air Horns orange FC 2100252 19 Air Horns black FC 2100253 20 Antenna FC 2100254 20 Antenn...

Page 34: ...2 49 58 25 46 32 63 84 83 65 67 47 73 75 74 76 68 69 86 99 41 56 55 53 59 57 64 24 14 34 35 43 42 39 40 38 94 92 54 54 92 81 85 80 79 77 78 90 70 89 48 93 93 37 45 36 19 20 18 21 22 4 97 26 13 16 27 2...

Page 35: ...her ID 0000025 57 CV board AG 0000007 w 2 female plugs 58 Volume pot BI 4500008 59 Screw IA 0000003 4 40X6 0mm round head 60 Screw IA 0000005 M2 5X4 0mm round head 61 Bracket IH 0000045 interior light...

Page 36: ...one number a copy of your sales receipt the Return Authorization number and a full description of the problem must be included to facilitate the repairs Please include the description regardless of wh...

Reviews: