After activation the motor
is too loud. It is not possi-
ble to suspend a load.
•
Current and voltage
too low
•
The capacitor is
damaged.
•
Supply correct cur-
rent and voltage
•
Replace the capacitor
Unusually loud noises
•
Incorrect lubrication
•
Transmission and
bearing damaged due
to wear and tear
•
Incorrectly mounted
•
Apply more grease
•
Check and replace
transmission and
bearing if needed
•
Check assembly and
repair element ma-
king the noise
Incorrect power supply
to hoist
•
No earthing
•
Internal cabling in
contact with the
housing
•
Check or connect
earth
•
Check internal cabling
The traverse mechanism
does not work
•
The traverse button
is faulty
•
Repair or adjust the
traverse button
The motor is unable to lift
the load
•
Continuous operati-
on leads to excessive
build up of heat in the
internal motor coils
and may even lead to
it burning out
•
Cool the motor and
then start it up as per
normal