User’s Manual

SP112C Series

 

5.6

 

Output Short Circuit Protection:  
When the rear output terminal or PoE output be short circuit, 
protection be active, the product stop output and auto-recover 
when the terminal back to normal connection. 

5.7

 

Battery Output Current Limit:  
The fuse will be burnt when battery output current over 15A 

5.8

 

Load Output Voltage Limit: 
The output voltage of the rear terminal is the same as battery. 

5.91   POE Charge Voltage : 

Float = 13.4V ± 0.2V Equalize 

= 14.2V ± 0.2V 

5.92   SOLAR Charge Voltage : 

Charge Voltage = 14.4 V ± 0.2V 

6. GENERAL DESCRIPTION

6.1   Operation Temperature:

-40  -  +50 Degree

6.2   Storage Temperature:

-40  -  +85 Degree

6.3   Operation Humidity:

5%  -  90% non-condensing

6.4   Cooling:

Free air cooling

6.5   SIZE

150*118*40mm (L*W*H)
DIN rail mountable

Summary of Contents for SP112C Series

Page 1: ...SP112C Series Solar PoE Battery Charger USER S MANUAL...

Page 2: ...2C 56DA DIN Rail Mountable Support Gigabit Ethernet Applications Remote Power Systems Surveillance Sensors Wireless Station AP Client Repeaters UPS Systems Lighting Fences Gates Protection Battery Pol...

Page 3: ...olarity reverse indicator the LED lights when the battery polarities are reversed detail description see Sec 5 1 6 IN PoE Input Jack the lower RJ45 jack used for PoE input Allowed input voltage 36 57V...

Page 4: ...tand alone without battery connected 4 When a solar panel and PoE input are connected to the charger if the voltage of solar panel is higher than 15V then solar panel is always the main power source o...

Page 5: ...l SP112C Series 8 It can be two separate outputs on the rear panel make sure the total draw is not over the limit 9 The V of PoE input Solar input and battery are not the same grounding must be proper...

Page 6: ...TPUT Model No Output 1 at rear terminal Output 2 at front upper RJ45 RP SP112C 24B 12V 10A as Bat Volt 24V 1 25A regulated RP SP112C 48A 12V 10A as Bat Volt 48V 0 625A 12 36 regulated RP SP112C 48B 12...

Page 7: ...will be disable if there is a PoE power sources be connected when the battery polarities reversed the battery will be disconnected 5 2 Battery Over Discharge Protection Cuts off the load when the bat...

Page 8: ...ill be burnt when battery output current over 15A 5 8 Load Output Voltage Limit The output voltage of the rear terminal is the same as battery 5 91 POE Charge Voltage Float 13 4V 0 2V Equalize 14 2V 0...

Page 9: ...I_DA power Data pair A 3 Vdc BI_DB power Data Pair B Vdc BI_DB power Data Pair B 4 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 5 Vdc BI_DC power Data Pair C Vdc BI_DC power Data Pair C 6 V...