1.  Connect the battery to the BAT terminal. Make sure the polarities are 

correctly connected. Sequentially connect the solar panel to SOL terminal 
and connect AC source to AC inlet. (If solar panel or AC source is 
installed before the battery, and if the polarities of the battery be reversed, 
then the battery will be disconnected.) 
 

2.  Make sure the battery is properly connected to the unit. If no battery is 

connected, then no voltage at BAT terminal. 

 

3.  When a solar panel and AC input are connected to the charger, if the 

voltage of solar panel is higher than 15V, then solar panel is always the 
main power source of the charger.  

 

 

4.  If only solar panel be used as the power source, then if solar panel 

voltage lower than 10.5V, will stop charging. The solar panel cannot be 
used stand alone without battery connected.  

 

5.  If only AC be used as the power source, then the load outputs will be 

powered even without battery connected. 

 

10 

LOAD : 

Load Terminal: wire size up to 12~16AWG, the output voltage is 
the same as battery voltage.  

11 

AC 

AC inlet: for 100~240VAC input. 

Summary of Contents for SOL20A12-56D-BT

Page 1: ...Mstronic Co Ltd SOL20A12 56D BT Solar AC Charge Controller Gigabit PoE Injector USER S MANUAL...

Page 2: ...bt handshake 19 rack mountable desktop mountable Applications Remote Power Systems Surveillance Sensors Wireless Station AP Client Repeaters UPS Systems Lighting Fences Gates Protection Battery Polar...

Page 3: ...attery and charging 4 LOA Loading indicator the LED lights when the rear panel output terminal is connecting to a device and offering power The LED always on when power ready 5 REV Battery polarity re...

Page 4: ...connected then no voltage at BAT terminal 3 When a solar panel and AC input are connected to the charger if the voltage of solar panel is higher than 15V then solar panel is always the main power sou...

Page 5: ...n no load connected 9 It can be two separate outputs on the rear panel make sure the total draw is not over the limit 10A 10 The solar input and battery are not the same grounding must be properly iso...

Page 6: ...e reversed the model will stop output and REV indicator light on When the battery be removed and re connected to terminal the function will be disable if there is AC power sources connected when the b...

Page 7: ...stop output and auto recover when the terminal back to normal connection 4 7 Battery Output Current Limit The fuse will be burnt when battery output current over 20A 4 8 Load Output Voltage Limit The...

Page 8: ...DD Data Pair D Vdc BI_DD power Data Pair D Note the model is isolated design the output or input can be shorted to ground FG 7 AC Input to Battery Charger Voltage Float 13 4V 0 3V Equalize 14 2V 0 3V...

Reviews: