background image

User’s Manual

                                                                              SOL20A12-56D-BT

 

 
 

 

6.0 

 

RJ45

 

pinout

: @1000M 

RJ-45 Input (Data Only) 

RJ-45 Output (Data & Power) 

Pin 

Symbol 

Description 

Symbol 

Description 

BI_DA+ 

Data Pair A+ 

-Vdc +BI_DA+ 

power(-)+Data Pair A+ 

BI_DA- 

Data Pair A- 

-Vdc +BI_DA- 

power(-)+Data pair A- 

BI_DB+ 

Data Pair B+ 

+Vdc +BI_DB+ 

power(+)+Data Pair B+ 

BI_DC+ 

Data Pair C+ 

+Vdc + BI_DC+ 

power(+)+Data Pair C+ 

BI_DC- 

Data Pair C- 

+Vdc + BI_DC- 

power(+)+Data Pair C- 

BI_DB- 

Data Pair B- 

+Vdc +BI_DB- 

power(+)+Data Pair B- 

BI_DD+ 

Data Pair D+ 

-Vdc + BI_DD+ 

power(-)+Data Pair D+ 

BI_DD- 

Data Pair D- 

-Vdc + BI_DD- 

power(-)+Data Pair D- 

Note : the model is isolated design, the /- or input +/- can be shorted to ground (FG). 

 

7.  AC Input to Battery Charger Voltage : 

Float = 13.4V ± 0.3V 
Equalize = 14.2V ± 0.3V 
 

8.  SOLAR to Battery Charger Voltage : 

       Charge Voltage = 14.4 V ± 0.2V 
 

9.  BATTERY OUTPUT CONVERT TO : 

9.1  802.3af/at/bt POE OUTPUT (Pin: 3/6/4/5 = + , 1/2/7/8 = -) 

 

OUTPUT 

56V 

Max.  Current 

1.25A 

Max.  Watts 

70W 

   

9.2

 

 DC = 10A Output. Same as battery voltage 

 

 

10.  Series models 

 

Model 

SOL20A12-56B1N 

SOL20A12-56A1N 

SOL20A12-56A1R 

Output 1 

(upper RJ45) 

56V/0.625A 

(regulated) 

(4/5+, 7/8-) 

56V/0.625A 

(regulated) 

(1/2-, 3/6+) 

56V/0.625A 

(regulated) 

(1/2+, 3/6-) 

Output 2 

(rear terminal) 

12V/10A 

(as Bat. Volt.) 

12V/10A 

(as Bat. Volt.) 

12V/10A 

(as Bat. Volt.) 

 

 

Summary of Contents for SOL20A12-56D-BT

Page 1: ...Mstronic Co Ltd SOL20A12 56D BT Solar AC Charge Controller Gigabit PoE Injector USER S MANUAL...

Page 2: ...bt handshake 19 rack mountable desktop mountable Applications Remote Power Systems Surveillance Sensors Wireless Station AP Client Repeaters UPS Systems Lighting Fences Gates Protection Battery Polar...

Page 3: ...attery and charging 4 LOA Loading indicator the LED lights when the rear panel output terminal is connecting to a device and offering power The LED always on when power ready 5 REV Battery polarity re...

Page 4: ...connected then no voltage at BAT terminal 3 When a solar panel and AC input are connected to the charger if the voltage of solar panel is higher than 15V then solar panel is always the main power sou...

Page 5: ...n no load connected 9 It can be two separate outputs on the rear panel make sure the total draw is not over the limit 10A 10 The solar input and battery are not the same grounding must be properly iso...

Page 6: ...e reversed the model will stop output and REV indicator light on When the battery be removed and re connected to terminal the function will be disable if there is AC power sources connected when the b...

Page 7: ...stop output and auto recover when the terminal back to normal connection 4 7 Battery Output Current Limit The fuse will be burnt when battery output current over 20A 4 8 Load Output Voltage Limit The...

Page 8: ...DD Data Pair D Vdc BI_DD power Data Pair D Note the model is isolated design the output or input can be shorted to ground FG 7 AC Input to Battery Charger Voltage Float 13 4V 0 3V Equalize 14 2V 0 3V...