background image

User’s Manual

                                                                              SOL20A12-56D-BT

 

 
 

 

6.  When charge from solar panel, as the battery full and turn to floating 

stage, the CHA light will start flash.  

 

7.  When charge from AC, as the battery full, the CHA light will be turn off. 

 

8. 

When battery connect to BAT terminal and with valid voltage, then the 

LOA indicator will always light on even no load connected.

 

 

9.  It can be two separate outputs on the rear panel, make sure the total 

draw is not over the limit 10A. 

 

10. The solar input, and battery(-) are not the same grounding, must be 

properly isolated. 

 

11. When all power sources failed, the loads will be powered from battery 

immediately with no interrupted, until the battery voltage lower than 11V 
+/- 0.3V.  

 
12. When any power source recover, the battery will be charged if the 

battery voltage more than 6V. when the battery voltage back to 12V, the 
load will be powered again. 

 

Summary of Contents for SOL20A12-56D-BT

Page 1: ...Mstronic Co Ltd SOL20A12 56D BT Solar AC Charge Controller Gigabit PoE Injector USER S MANUAL...

Page 2: ...bt handshake 19 rack mountable desktop mountable Applications Remote Power Systems Surveillance Sensors Wireless Station AP Client Repeaters UPS Systems Lighting Fences Gates Protection Battery Polar...

Page 3: ...attery and charging 4 LOA Loading indicator the LED lights when the rear panel output terminal is connecting to a device and offering power The LED always on when power ready 5 REV Battery polarity re...

Page 4: ...connected then no voltage at BAT terminal 3 When a solar panel and AC input are connected to the charger if the voltage of solar panel is higher than 15V then solar panel is always the main power sou...

Page 5: ...n no load connected 9 It can be two separate outputs on the rear panel make sure the total draw is not over the limit 10A 10 The solar input and battery are not the same grounding must be properly iso...

Page 6: ...e reversed the model will stop output and REV indicator light on When the battery be removed and re connected to terminal the function will be disable if there is AC power sources connected when the b...

Page 7: ...stop output and auto recover when the terminal back to normal connection 4 7 Battery Output Current Limit The fuse will be burnt when battery output current over 20A 4 8 Load Output Voltage Limit The...

Page 8: ...DD Data Pair D Vdc BI_DD power Data Pair D Note the model is isolated design the output or input can be shorted to ground FG 7 AC Input to Battery Charger Voltage Float 13 4V 0 3V Equalize 14 2V 0 3V...

Reviews: