6. When charge from solar panel, as the battery full and turn to floating
stage, the CHA light will start flash.
7. When charge from AC, as the battery full, the CHA light will be turn off.
8.
When battery connect to BAT terminal and with valid voltage, then the
LOA indicator will always light on even no load connected.
9. It can be two separate outputs on the rear panel, make sure the total
draw is not over the limit 10A.
10. The solar input, and battery(-) are not the same grounding, must be
properly isolated.
11. When all power sources failed, the loads will be powered from battery
immediately with no interrupted, until the battery voltage lower than 11V
+/- 0.3V.
12. When any power source recover, the battery will be charged if the
battery voltage more than 6V. when the battery voltage back to 12V, the
load will be powered again.