background image

User’s  Manual

                                                                               

          PSE-SW5G  series 

 

 
MSTRONIC CO., LTD.                                                          
                                                                       

 

7

 

The terminal block on the rear panel should be wired as detailed below:   

 

   

 

 

The DIN-4P connector on the rear panel also used for power input, you can use an AC/DC adapter 

with DIN-4P connector directly, recommends adaptor MS-180-18 or MS-180-24 as detailed below: 

(OPTION) 

 

 

MS-180-18 

MS-180-24 

Maximum output 

18VDC/8.33A 

24VDC/6.25A 

 

 

*Ethernet Port Wiring 

 

The PoE switch family supports one RJ-45 uplink (port 5 with PoE PD) and four RJ-45 ports (port 

1~4 with PoE PSE) with automatic MDI/MDI-X crossover, auto-sense for speed and duplex for 

10Base-T, 100Base-TX or 1000Base-T connection. Automatic MDI/MDI-X crossover allows you 

to connect to other devices (switches, hubs, or workstations etc.), without regard to using 

straight-through or crossover cabling. 

   

Port 1 to 4 provides Power over Ethernet function that delivers DC power through the data pairs C 

& D (pin 4,5 and pin 7,8) (mode B) to the PD. Port 5 provides Power Device function that receive 

power from 4 pairs or 2 pairs Ethernet cable. 

  The following tables describe the wiring diagram of straight-through and crossover cabling. The 

crossover cables simply cross-connect the transmit lines at each end to the receive lines at the 

opposite end. 

Summary of Contents for PSE-SW5G-25 4 Series

Page 1: ...USER S MANUAL MSTRONIC CO LTD PSE SW5G 25x4 5 Port PoE Switch Extender Repeat Ethernet and PoE...

Page 2: ...ual PSE SW5G series MSTRONIC CO LTD 2 1 General Information 2 Hardware Description LED Indicators Power Wiring Ethernet Port Wiring PD Port Wiring Network Application 3 Technical Specification 3 3 3 5...

Page 3: ...3af and IEEE802 3at standard to receive and deliver both Ethernet data and DC power through the traditional UTP or STP cable The PoE Switch can extend Ethernet data and DC power up to 200 meters This...

Page 4: ...tected 1000Mbps but no communication activity is detected Green Blinking This port is transmitting to or receiving package from another device at 1000Mbps Yellow A network device is detected 10Mbps or...

Page 5: ...pin out Iout Output Wattage Remark PSE SW5G25A4 12 36VDC P3 44 57VDC POE 56VDC 1236 0 625A 35W port 802 3at PSE SW5G25B4 12 36VDC P3 44 57VDC POE 56VDC 4578 0 625A 35W port 802 3at PSE SW5G25D4 12 36...

Page 6: ...Ethernet cable as detailed below Mode A PSE SW5G25A4 Data pair A plus V on line 1 and 2 Data pair B plus V on line 3 and 6 Data pair C on line 4 and 5 Data pair D on line 7 and 8 Mode B PSE SW5G25B4 D...

Page 7: ...matic MDI MDI X crossover auto sense for speed and duplex for 10Base T 100Base TX or 1000Base T connection Automatic MDI MDI X crossover allows you to connect to other devices switches hubs or worksta...

Page 8: ...in 5 Connect an Ethernet cable into any switch port and connect the other side to your attached device The Link Act LED green or yellow will light up when the cable is correctly connected Refer to the...

Page 9: ...ative Vport Positive Vport 2 Negative Vport Positive Vport 3 Positive Vport Negative port 4 Positive Vport 5 Positive Vport 6 Positive Vport NegativeVport 7 Negative Vport 8 Negative Vport Be sure the...

Page 10: ...from a PoE midspan and provide power to the PD which follows the IEEE 802 3af at standard in the network The PoE Switch can be installed in a more appropriate position for better performance to extend...

Page 11: ...negotiation Switch technology store and forward Protocols CSMA CD Flow control IEEE802 3x full duplex back pressure half duplex Data transmission rate 1488000pps for1000base T 148800pps for 100base T...

Page 12: ...detection IEEE802 3af IEEE802 3at 2 event classification signaling PoE protection Over temperature over current over under voltage LEDs Link Activity Green ON Green Blinking 1000Mbps Yellow Yellow Bli...

Page 13: ...Protection on data pairs Signal Operating Voltage Data 5V Clamping Voltage Data 16 5V I PP 5A t p 8 20 s I O pin to GND Peak Pulse Current 20A tp 8 20 s Pin Protected All 8 pin protected data input M...