3

1. General Information 

 

The PSE-SW5G PoE (Power Over Ethernet) Switch family provides four 10M/100M/1000M TX 

ports with PoE PSE function plus one 10M/100M/1000M TX up-link port with PoE PD function. It 

accepts power from PoE power souring equipment (PSE) and delivers power to PoE powered 

device (PD), which are compliant with IEEE802.3af and IEEE802.3at standard to receive and 

deliver both Ethernet data and DC power through the traditional UTP or STP cable. The PoE 

Switch can extend Ethernet data and DC power up to 200 meters.

 

This manual will help you to 

install and maintain the PoE switch. Installation of the PoE switch is very easy and you can start to 

use the product as soon as it has powered up. 

 

 

2. Hardware Description 

*LED Indicator 

 

There are 12 LEDs on the PoE switch to indicate the status of power and signal. The following 

section describes the functions of each LED indicator. 

 

Front panel detail 

 

 

 

 

Summary of Contents for PSE-SW5G-25 4 Series

Page 1: ...USER S MANUAL MSTRONIC CO LTD PSE SW5G 25x4 5 Port PoE Switch Extender Repeat Ethernet and PoE...

Page 2: ...ual PSE SW5G series MSTRONIC CO LTD 2 1 General Information 2 Hardware Description LED Indicators Power Wiring Ethernet Port Wiring PD Port Wiring Network Application 3 Technical Specification 3 3 3 5...

Page 3: ...3af and IEEE802 3at standard to receive and deliver both Ethernet data and DC power through the traditional UTP or STP cable The PoE Switch can extend Ethernet data and DC power up to 200 meters This...

Page 4: ...tected 1000Mbps but no communication activity is detected Green Blinking This port is transmitting to or receiving package from another device at 1000Mbps Yellow A network device is detected 10Mbps or...

Page 5: ...pin out Iout Output Wattage Remark PSE SW5G25A4 12 36VDC P3 44 57VDC POE 56VDC 1236 0 625A 35W port 802 3at PSE SW5G25B4 12 36VDC P3 44 57VDC POE 56VDC 4578 0 625A 35W port 802 3at PSE SW5G25D4 12 36...

Page 6: ...Ethernet cable as detailed below Mode A PSE SW5G25A4 Data pair A plus V on line 1 and 2 Data pair B plus V on line 3 and 6 Data pair C on line 4 and 5 Data pair D on line 7 and 8 Mode B PSE SW5G25B4 D...

Page 7: ...matic MDI MDI X crossover auto sense for speed and duplex for 10Base T 100Base TX or 1000Base T connection Automatic MDI MDI X crossover allows you to connect to other devices switches hubs or worksta...

Page 8: ...in 5 Connect an Ethernet cable into any switch port and connect the other side to your attached device The Link Act LED green or yellow will light up when the cable is correctly connected Refer to the...

Page 9: ...ative Vport Positive Vport 2 Negative Vport Positive Vport 3 Positive Vport Negative port 4 Positive Vport 5 Positive Vport 6 Positive Vport NegativeVport 7 Negative Vport 8 Negative Vport Be sure the...

Page 10: ...from a PoE midspan and provide power to the PD which follows the IEEE 802 3af at standard in the network The PoE Switch can be installed in a more appropriate position for better performance to extend...

Page 11: ...negotiation Switch technology store and forward Protocols CSMA CD Flow control IEEE802 3x full duplex back pressure half duplex Data transmission rate 1488000pps for1000base T 148800pps for 100base T...

Page 12: ...detection IEEE802 3af IEEE802 3at 2 event classification signaling PoE protection Over temperature over current over under voltage LEDs Link Activity Green ON Green Blinking 1000Mbps Yellow Yellow Bli...

Page 13: ...Protection on data pairs Signal Operating Voltage Data 5V Clamping Voltage Data 16 5V I PP 5A t p 8 20 s I O pin to GND Peak Pulse Current 20A tp 8 20 s Pin Protected All 8 pin protected data input M...