USER MANUAL
MCL100
Pág.
17
R
v0
7
5.
If moisture or condensation appears in the beacon:
Possible reasons:
a)
Beacon not properly closed.
b)
O-ring is damaged.
Solutions:
a)
Retire the beacon from its site and move it to a dry site. Open and air it during
a few days. Put silica gel or any secant to absorb the humidity.
b)
Check the O-ring and replace it if necessary.
c)
Close the lens cover appropriately. Screws must be tightened in cross, to
exercise the same strength in the whole O-ring. Check the O-ring is in correct
position.
6.
If the beacon doesn’t respond to the PC:
Possible reasons:
a)
RS232 communication cable failure.
b)
PC or software failure.
c)
MF06 failure.
Solutions:
a)
Check with other communication table.
b)
Reinstall software or try with other PC.
c)
Test MF06 flasher and substitute if necessary.