background image

M  E  A  S  U  R  E  M  E  N  T    S  Y  S  T  E  M  S    I  N  T  E  R  N  A  T  I  O  N  A  L

MSI-4300 Porta-Weigh Plus/5 Key  

•  

User Guide  

   Page 3

TABLE OF CONTENTS

Introduction ............................................................ 4
Specifications ......................................................... 4
Features ................................................................... 5
Unpacking ............................................................... 6
Battery Removal and Replacement ........................ 6
Battery Life ............................................................. 7
Battery Charger ....................................................... 7
Batteries .................................................................. 8

Optional Alkaline Battery Power ..................... 8

Keyboard Operations ............................................ 10

Keyboard Features ......................................... 10

Power Switch ........................................................ 11
Zero Switch .......................................................... 11
Net/Gross Switch .................................................. 12
Tare In/Tare Out Switch ....................................... 12

To remove the Tare Value ............................... 13

Test Switch ........................................................... 13
Calibration and Setup ........................................... 14

Switch Functions during Calibration & Setup 14

Enabling Calibration and Setup ............................ 14
Calibrate Setup Menu ........................................... 15
Standard Calibration ............................................. 15
Fine Calibration .................................................... 16
Cal with Rcal value (Calibrate with the
Resistor Calibration number) ............................... 16
To Enable/Disable AZM (Auto Zero
Maintenance) ........................................................ 17
To Set the Legal Standard ..................................... 17
Other Setup Functions .......................................... 17

Filter ............................................................... 17
Auto Off ......................................................... 17
Lighting .......................................................... 17
Remote ........................................................... 17
Setpoint .......................................................... 17
Disable Setpoint ............................................. 20
Contrast .......................................................... 21

To Initialize the Scale ........................................... 21
Infrared Remote Control Option .......................... 22
Remote Control Battery Replacement .................. 23
Infrared Remote Comments ................................. 24
Proper Loading Procedures .................................. 26
The MSI Limited Warranty .................................. 27

Summary of Contents for 4300/5

Page 1: ...User Guide Quality Industrial Weighing and Force Measurement Equipment Measurement Systems International PORTA WEIGH PLUS CRANE SCALES 5 KEY VERSION MSI4300 5...

Page 2: ...M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L Page 2 MSI 4300 Porta Weigh Plus 5 Key User Guide...

Page 3: ...Value 13 Test Switch 13 Calibration and Setup 14 Switch Functions during Calibration Setup 14 Enabling Calibration and Setup 14 Calibrate Setup Menu 15 Standard Calibration 15 Fine Calibration 16 Cal...

Page 4: ...d fully shock mounted and marine proof construction makes for a rugged and reliable overhead scale 6 Digit Weight Indication 8 Character Message Display Units lb kg t METRIC t International Motion Ico...

Page 5: ...eric characters Also used for menu prompts Display illumination uses rugged long life light emmitting diode LED backlighting coupled with a transflective liquid crystal display providing optimum displ...

Page 6: ...ACEMENT 1 Turn the MSI 4300 Off 2 With one hand hold the battery access door to prevent it from falling 3 Rotate the two cam lock knobs on the access door counter clockwise until the door latches dise...

Page 7: ...vailable life Due to the small maintenance discharge imposed on the battery by the MSI 4300 electronics do not store the MSI 4300 with the battery inside the scale for extended periods longer than 7 1...

Page 8: ...recommends obtaining a spare battery so one can always be on the charger BATTERIES Optional Alkaline Battery Power 8 Standard D cells Alkaline type is preferred but standard Carbon Zinc can also be us...

Page 9: ...M E A S U R E M E N T S Y S T E M S I N T E R N A T I O N A L MSI 4300 Porta Weigh Plus 5 Key User Guide Page 9 This page intentionally left blank...

Page 10: ...zero any weight on the scale which causes the scale to go into the NET mode When in NET mode pushing TARE will clear the TARE value and the scale will revert to the GROSS mode 5 TEST When pushed this...

Page 11: ...all internal operations are checked and any nonconformance causes an error message to be displayed 4 UK LFT units only ZERO User is prompted to push the zero key 1 20 zero range If the weight is in i...

Page 12: ...Rules for Use 1 Does not operate in the GROSS mode 2 NET GROSS will work even when the scale is in motion Action Not in NET mode Tare No Action display continues to read the Gross weight only In NET m...

Page 13: ...ibration number Action To start the text sequence push TEST 1 All digits 7 segment and 16 segment count once from 0 to 9 All annunciators are tested 16 segment displays also go through 2 Battery condi...

Page 14: ...n 2 ZERO Used to zero the scale during calibration or CLEAR during setups 3 NET GROSS Used to scroll through menu items Used in FINE CAL as UP 4 TARE IN OUT Used only in FINE CAL as DOWN 5 TEST Used a...

Page 15: ...ST eight steps with numerics at 123456 and message reading CONTRAST EXIT Push ENTER TEST to quit setup HI SET PT HI VALUE DISABLED GROSS NETGROSS RESPONSE NORMAL BLANKLCD BLINKLCD EXIT LO SET PT LO VA...

Page 16: ...2 Use the SELECT NET GROSS key to scroll to the FINE CAL message Push ENTER TEST 3 Pick up a test weight of at least 50 of capacity The weight is indicated on the numeric digits WARNING This function...

Page 17: ...pushing the key behind the seal port 2 Use the SELECT NET GROSS key to scroll to the AZM message Push ENTER TEST 3 Use the SELECT NET GROSS key to scroll through the AZM options When the desired mode...

Page 18: ...it off LIGHTING The light emitting diode LED backlight is normally controlled by a photocell that detects ambient light and determines if the backlight should be on or off AUTOMATIC mode Should the us...

Page 19: ...Push ENTER The first se lection is DISABLED This mode allows the user to program a setpoint without the setpoint actually operating To enable the setpoint push SELECT until either the GROSS mode or th...

Page 20: ...peration use SELECT until the message EXIT appears and push ENTER or push CLEAR no shift required This returns you to the Setup Menu Again push CLEAR to get out of the menu and back to standard scale...

Page 21: ...immediately by the Cal Switch The Scale reads RESET 2 Use the SELECT NET GROSS key to scroll to UNITS Push ENTER TEST 3 Use the SELECT NET GROSS key to scroll to the desired unit of measure Push ENTE...

Page 22: ...achieve the maximum operation range The shape of the remote is designed to help in aiming Aiming becomes less critical as the distance decreases The differences between front panel operation and remot...

Page 23: ...While in NET mode push TARE followed by PRINT Caution Do not accidently push the Tare key while in Gross mode as this will clear the old tare and establish a new tare Numeric Entry The Tare memory val...

Page 24: ...and the battery is fresh 7 Replace the front panel switch assembly by centering it over the open area and pressing evenly around the edges until it seals 8 Replace the three screws Make sure the scre...

Page 25: ...he number entry otherwise the ID will remain as before As shipped any Measurement Systems International infrared remote will operate any Porta Weigh Plus It is possible by special order to encode the...

Page 26: ...MORY CLEAR SELECT TEST T 0 ZERO NET GROSS TARE TOTAL POWER VIEW SHIFT DO NOT USE MULTIPLE ATTACHMENTS DO NOT ENTER SETUP PEAK HOLD TARE MEMORY CLEAR SELECT TEST T 0 ZERO NET GROSS TARE TOTAL POWER VIE...

Page 27: ...r alterations made by others except those repairs or alterations made with its specific written consent nor shall the Company be liable for any damages or delays whether caused by defective workmanshi...

Reviews: