The bench ensures the operation at the temperature from +100C up to +400C and relative air
humidity from 10% up to 90%.
After transporting the bench at an ambient temperature below 0°C, before turning it on, it should
be kept at operating temperature for at least 24 hours.
Before operation of the bench it is necessary to connect:
- electric network 230V (single-phase) with a grounding contact, the permissible current of which
is not less than 16 A. If the socket is removed from the installation site of the bench, it is necessary
to complete the electrical network and install the socket.
- A compressed nitrogen source equipped with a pressure regulator with an output working
pressure of 6 Bar and providing the capacity at a working pressure of at least 100 l/min (m
3
/h).
The connector for the SAE stand 1/4" to connect the compressed nitrogen source is located on
the left side of the bench.
Figure 4. Location of the SAE 1/4" compressed nitrogen connector
6. COMPRESSOR DIAGNOSIS
The diagnostic procedure includes the following steps:
1. In the database of the bench, find and select the model of the diagnosed unit. The stand will
display the numbers of cables and fittings necessary for its diagnosis.