English
User manual
11
5. Using the open-end wrench or end head, check the electro valve filter cover (position 1 fig. 5)
counterclockwise until disconnection from the filter bowl.
5.1. Assess the condition of the sealing rings. Replace them if necessary.
5.2. Replace the filter element.
5.3. Place the filter cover in place and rotate it clockwise.
6. Place the back panel on it place and bolt.
Figure 5. Arrangement of bench elements requiring maintenance:
1 - filter; 2 - oil separator; 3 - combined filter;
4 - connector of waste oil level sensor.
WARNING!
When maintaining the stand, you must use personal protective equipment.
7.2. Test bench software update
To update the software of the bench you will need a USB Type-C Flash drive up to 32Gb (maximum)
formatted into the Fat32 file system.
The upgrade procedure is as follows:
- Download the file with the latest version of the software from the site servicems.eu, which is
in the MS112 product card;
- Copy the «Update.bin» file to the USB Type-C Flash Drive root directory;