CLEANING
1. Apply alcohol to a Q-Tip applicator.
a. Wipe threads on ICM unit and wipe Jam Nut (Dull Surface Finish).
b. Wipe threads of ICM port of Quick-Fill Block.
2. Let alcohol dry for 15 seconds.
INSPECTION
1. Inspect the threads of ICM unit, Jam Nut, and Quick-Fill Block for any damage.
SPOOL
Note:
If your apparatus is equipped with the Quick-Fill System and the ICM unit, it will have
the Spool included. Make sure Spool is in the ICM unit.
1. Check that the spool is present in the ICM unit. If the spool is in the Quick-Fill Adapter
Block, remove spool from Quick-Fill Block.
2. Inspect spool for damage. Replace O-Rings (P/N 638167) and Back-Up Rings (P/N 63527).
Apply a thin film of Christo-Lube lubricant to O-Rings and Back-Up Rings.
CAUTION!
Only apply a thin film of lubricant to O-Rings and Back Up Rings. Not to spool.
3. Insert the spool into the ICM unit. The spool's larger-diameter hole must face toward the
ICM unit.