ManualNightFighterInstallation.doc  

 

Prnt Spec. 10000005389(B)   Mat. 10035581 

07/23/02  

 

Page 11 of 15 

 

• 

Insert the spool into the pressure gauge Redundant Alarm, or ICM.  The spool's larger-

diameter hole must face 

toward

 the gauge. 

• 

Thread the gauge (or Redundant Alarm) into the Transmitter Adapter Block.  The gauge 

must screw in at least 6 1/2 turns with the jam nut firmly against the Transmitter Adapter 

Block. 

 

Note:

  See Installation Instructions for ICM 

 

CAUTION! 

Do not tighten the gauge by hand.  Use wrenches. 

 

WARNING! 

Do not try to screw the small-diameter (tapered thread) gauge (P/N 495764 or 495765) into 

the Transmitter Adapter.  Use the larger-diameter gauge (P/N 10003610 or P/N 10003611) 

with a straight thread.  Failure to follow this precaution can result in serious personal 

injury or death. 

 

• 

If the gauge is not facing out (away from the shoulder pad), unthread the gauge 

not more 

than one turn

 to obtain this alignment.  Hold the gauge to prevent turning.  Tighten the jam 

nut against the adapter block to a torque of 200-225 in.-lbs. 

 

WARNING! 

Do not unthread the gauge more than one full turn.  The gauge-adapter connection may 

leak, resulting in serious personal injury or death. 

 

• 

Make sure the gauge guard (alarm boot on Redundant Alarm units) is in place around the 

gauge. 

• 

Check that the dust cover is installed on the gauge hose above the Transmitter Adapter. 

Summary of Contents for NightFighter

Page 1: ...are voided if the product is not used according to the instructions in this manual We encourage our customers to write or call for a demonstration of this equipment prior to use or for any additional...

Page 2: ...ing Once the release is lifted you can remove the cover by pulling it away from the housing You must tilt the cover and work it over one adapter bayonet at a time Removing the Component Housing Cover...

Page 3: ...3 02 Page 3 of 15 CAUTION Be careful that you do not damage internal parts of the component housing assembly exhalation valve spring retainer or speaking diaphragm once the cover is removed Note The f...

Page 4: ...acket into component housing ring hole Tighten firmly Replace the Component Housing Cover for MMR MMR with Slide Connection and BMR Ultra Elite Facepiece CAUTION Be careful that you do not damage inte...

Page 5: ...ng Install the Phillips screws through the bracket spacer cover and metal top of bracket and tighten 6 Verify each of the following features a The adapter bayonets are locked into a horizontal positio...

Page 6: ...2 Insert the tab on the top of the cover into the slot in the bottom of the lens ring 3 Press in on the front of the cover until the cover hook snaps into place 4 Line up the screw holes in the cover...

Page 7: ...00 2000 Plus installed You must be a Certified Repairperson to perform the installation procedures which follow COMMON PARTS 638166 O ring 635277 Backup ring 3 10003605 Spool REQUIRED TOOLS The tools...

Page 8: ...der gauge line hose you must remove the gauge from the MMR harness gauge hose 1 Close the bypass valve fully WARNING Do not disconnect the alarm coupling nut when pressure is shown on the harness gaug...

Page 9: ...gauge hose fitting 2 Using the O ring removal tool remove the O ring and backup ring from the end of the gauge hose fitting Note You can salvage the Quick Fill Coupling from the exiting block 3 Place...

Page 10: ...up ring Place the backup ring in the groove on the end of the hose fitting 2 Apply a thin film of Christo Lube lubricant to a newO ring Place the O ring in the groove on the end of the hose fitting 3...

Page 11: ...495764 or 495765 into the Transmitter Adapter Use the larger diameter gauge P N 10003610 or P N 10003611 with a straight thread Failure to follow this precaution can result in serious personal injury...

Page 12: ...us cylinder 1 Be sure the cylinder valve is completely closed 2 Be sure that nothing blocks the regulator outlet Open the bypass valve to relieve pressure in the system REMOVING ICM FROM THE QUICK FIL...

Page 13: ...tus is equipped with the Quick Fill System and the ICM unit it will have the Spool included Make sure Spool is in the ICM unit 1 Check that the spool is present in the ICM unit If the spool is in the...

Page 14: ...torque to 200 225 in lbs with a thin crowsfoot wrench LEAK TESTING Checking for leaks and proper operation 1 Follow the User s Instructions supplied with the Air Masks to connect the alarm to a fully...

Page 15: ...should indicate the pressure in the cylinder 4 Close the cylinder valve and watch the remote gauge There should be no drop in pressure if the apparatus is leak tight If the gauge needle moves check t...