background image

 

 

26E, Kibalchicha str., 192174,                                    Phone: +7 (812) 622-23-10                                                     [email protected] 
St Petersburg, Russia                                                Fax: +7 (812) 362-76-36                                                          www.unicont.com 
 
 

 

Limited Liability Company 

NPK MORSVYAZAVTOMATICA

 

 

 

 

 

 
 
 
 
 
 
 

 

SUMMATOR-COMBINER OF NMEA  

SIGNAL (SENTENCES)  

NC-217  

 

Operating manual 

 

 
 

 

Summary of Contents for NC-217

Page 1: ...192174 Phone 7 812 622 23 10 info unicont com St Petersburg Russia Fax 7 812 362 76 36 www unicont com Limited Liability Company NPK MORSVYAZAVTOMATICA SUMMATOR COMBINER OF NMEA SIGNAL SENTENCES NC 2...

Page 2: ...Marking and sealing 13 1 6 Packaging 13 2 INTENDED USE OF THE PRODUCT 14 2 1 Operational limitations 14 2 2 Usage preparations 14 2 3 Intended use 15 3 TECHNICAL SERVICE OF THE PRODUCT 21 3 1 General...

Page 3: ...ment the safety regulations and rules applicable in the field shall be observed Only those who have read and understood this document and those who have had special training shall be permitted to oper...

Page 4: ...nsumption W 20 Galvanic isolation from the mains Overvoltage protection Reverse polarity protection power supply connection Ports Interface input ports DATA_IN1 to DATA_IN4 4 RS 232 and RS 422 485 opt...

Page 5: ...ports The data packet received on the outputs of DATA_I O 1 and DATA_I O2 ports is repeated to the ports OUT1 to OUT12 according to the customer s settings while there are data on DATA_I O 1 the Prod...

Page 6: ...fier Purpose 1 LED indicator Power To display power status 2 Grounding stud M6x20 Main grounding element 3 Cable gland MG 20 To connect power supply 4 MG 16 To connect input data 5 To connect output d...

Page 7: ...4 The Product s output ports allow for connection of NMEA 0183 receivers with RS 422 485 input interfaces and RS 232 ports OUT1 to OUT6 see figure 3 Power supply of NMEA signal receivers may be option...

Page 8: ..._I O1 and DATA_I O2 ports NC 217 may be connected to PC through USB interface by a standard USB cable type A plug USB type A plug The Product s board is equipped with a USB connector type A to connect...

Page 9: ...supply voltage failure on POWER IN terminal of the Product If a user needs to ensure alarm signaling of the Product s power failure along with the main standby ports switching AU 106 should be powere...

Page 10: ...DATA_I O1 and DATA_I O2 are outfitted with Rt jumpers JP4 JP5 JP6 JP7 JP8 JP9 JP10 JP11 JP12 JP13 JP14 JP15 JP17 JP18 resistors terminators 120 Ohm used to match interface lines RS 422 and ter minals...

Page 11: ...is outfitted with an individual LED of channel activity D3 D5 D6 D7 D11 D12 D13 D16 D17 D20 D21 D24 D25 D26 D30 D34 that lights up with green if data are avail able on the port Each DATA_I O1 and DATA...

Page 12: ...12 NC 217 Operating manual Version 3 4 Figure 9 Layout of jumpers potentiometers and LEDs on the Product s PCB...

Page 13: ...Product in case of paint coating damage Abrasive cloth 0 06 0 06 m To polish surfaces of the Product in case of paint coating damage 1 5 MARKING AND SEALING The Product has a nameplate indicating nam...

Page 14: ...ctric installation and Safety rules for operation of electric installation while testing electrical circuits and insulation resistance 2 2 2 Visual check procedure Before switching the Product on a ob...

Page 15: ...ct is receiving NMEA mes sages via any channel the line displays the corresponding number otherwise the Product displays In a similar way the bottom line displays status of output channels To activate...

Page 16: ...Version 3 4 16 NC 217 Operating manual Figure 11 The structure of the Product s user menu...

Page 17: ...s Parity CRC checking Messages for ports OUT1 to OUT 12 and press Enter Make further settings depending on the selected parameter Note To return to port select menu as well as exit the port select men...

Page 18: ...s to cancel the made settings press key to return to the parameter select menu 2 3 3 5 Select CRC checking in the menu to provide the settings and LCD will display the following information see figure...

Page 19: ...menu item changes it is formed by select of NMEA sentences headlines received on DATA_I O 1 or DATA_I O 2 ports as part of single frame duplicate data packet To select sentences use and Enter to send...

Page 20: ...de scribed in table 4 Table 4 Capacity value under various options of coding Stop bits Parity Capacity 1 No 9 1 Even or Odd E 10 2 No E 10 2 Even or Odd E 11 Max output channel capacity is 115200 bit...

Page 21: ...erform the technical service semi annual TS S shall be performed by maintenance personnel on the running equipment 3 2 SAFETY FEATURES While performing the TS observe the instructions in 4 2 3 3 MAINT...

Page 22: ...es by clean cloth and dry them up 4 if varnish paint coating is damaged polish it with sand paper then clean with alcohol soaked cloth cover with varnish and dry up 1 person 5 minutes Check reliabilit...

Page 23: ...safety and received proper qualifications Check grounding of the Product before providing any repair works Put a poster DO NOT switch on Under Operation on a power supply switch in OFF position Replac...

Page 24: ...the interface cable Incorrect settings Provide correct settings The receiver is not receiving the data Interface cable is not connected Connect the interface cable Incorrect settings Provide correct...

Page 25: ...required storage conditions 5 to 40 with the concentration of dust oil moisture and aggressive impurities in the air within the required limits for the working areas of production facilities After sto...

Page 26: ...on in sealed and heated compartments sea transportation in dry service premises The Product must be transported in compliance with transportation rules applicable for each means of transport During lo...

Page 27: ...ties You can also send an over age equipment unit to the manufacturer for its further disposal Proper disposal of Product components allows avoiding possible negative environmental and health impacts...

Page 28: ...Version 3 4 28 NC 217 Operating manual APPENDIX INFORMATIVE OUTLINE AND INSTALLATION DIMENSIONS Figure A 1 The Product s outline and installation dimensions...