33
Cleaning and Disinfecting
G1 Air-Purifying Respirator (APR)
US
10.2 APR Adapter
WARNING!
Do NOT use cleaning products that contain hydrocarbons or solvents such as nitro-thinner.
Do NOT use radiant heat such as the sun or radiators to dry cleaned parts.
When a drying cabinet is used, make sure that the temperature is not more than 140°F (60°C).
Do a negative pressure seal test after every cleaning, disinfecting, and maintenance procedure,
and after every exchange of parts.
Failure to obey these warnings can result in serious injury or death.
10.2.1 Single Port
(6) To clean and rinse the pressure-demand exhalation valve,
use a blunt object to push in on the stem and flush the
valve with clean water.
(7) Let the facepiece air-dry. Do not put parts near a heater or
in direct sunlight to dry.
(8) Operate the exhalation valve manually to make sure that
it operates correctly.
(9) Do a negative pressure seal test before returning the
facepiece to service.
(1) Use the instructions on the label to prepare a solution of
Confidence Plus Germicidal Cleaner (PN 10009971) in a
bucket or sink.
(2) Remove the adapter cover.
(3) Submerge the adapter in the solution of Confidence Plus
Cleaner for a minimum of 30 seconds. If necessary, use a
sponge or soft brush to clean the adapter.