35
Cleaning and Disinfecting
G1 Air-Purifying Respirator (APR)
US
10.2.2 Twin Port
(1) Use the instructions on the label to prepare a solution of
Confidence Plus Germicidal Cleaner (PN 10009971) in a
bucket or sink.
(2) Remove the adapter cover.
(3) Submerge the adapter in the solution of Confidence Plus
Cleaner for a minimum of 30 seconds. If necessary, use a
sponge or soft brush to clean the adapter.
(4) Submerge the adapter cover in the solution of Confidence
Plus Cleaner for a minimum of 30 seconds. If necessary,
use a sponge or soft brush to clean the adapter cover.
(5) Rinse the adapter and adapter cover thoroughly in clean
water that is not more than 110°F (43°C) and is preferably
running and draining.
(6) Let the adapter and adapter cover air-dry. Do NOT put
parts near a heater or in direct sunlight.
(7) Operate the exhalation valve manually to make sure that
it operates correctly.