1) Facepieces which are regularly used should be
cleaned and disinfected as often as required. They
should be cleaned as soon as possible after each
use because perspiration or saliva that dries unto
the valves could cause malfunctions. The mask
must be disinfected at least before it is used by
another person.
2) For airtight packaged facepieces.
The manufacturing date of the full face mask is
marked behind the harness clasp on the lateral
flap of the faceblank. Example: Manufacturing
date April 2001
The manufacturing date of the exhalation valve
disc is marked on its outside,
Example: Manufacturing date 2001.
6
Storage
The mask should be stored in a carrier.
In order to prevent damage or distortion of the
mask, no additional objects must be stored in the
carrier.
Storage must be in clean, dry and normal climate,
i.e. cool, dry and free from hazardous material,
protected against light and radiant heat. It is
recommended to observe German Standard DIN
7716: 1982, and ISO 2230: 1973.
7
Accessories
7.1
Carrying Strap
For carrying full face mask and suspending it in
front of the chest.
8
Ordering Information
Description
Part No.
ADVANTAGE 3211 (S) small *)
100 27 727
ADVANTAGE 3221 (M) medium *)
100 27 726
ADVANTAGE 3231 (L) large *)
100 27 728
ADVANTAGE 3212 (S) small **)
100 42 732
ADVANTAGE 3222 (M) medium **)
100 42 733
ADVANTAGE 3232 (L) large **)
100 42 734
Nosecup M/L
(for Full Face Masks ADVANTAGE
3221, 3231, 3222 and 3232)
100 32 104
Nosecup S (for Full Face Mask
ADVANTAGE 3211, 3212)
100 32 103
Lens, Twin (with Gaskets, Dual Port)
100 32 112
Lens Ring, Kit
100 32 114
Inhalation Valve (20 pcs)
D2056 714
Exhalation Valve (10 pcs)
100 32 110
Gasket, Dual Port (10 pcs)
100 32 111
Connector Twin (with O-Ring and Clip) 100 32 106
Head Harness ADVANTAGE
100 32 102
Head Harness ADVANTAGE, Si
100 42 663
Cover for Connector
100 32 107
O-Ring for Connector (5 pcs)
100 32 108
Carrying Strap
100 32 100
Carrier ADVANTAGE
100 26 179
Prescription Spectacles
ADVANTAGE
according to type
MSA AUER Disinfectant 90, 2 litres
D2055 765
MSA AUER Disinfectant 90, 6 litres
D2055 766
MSA AUER Leak Test Kit
D6063 705
Adapters ADVANTAGE (for leak test)
100 17 835
*
*) with head harness ADVANTAGE
(textile neck strap)
100 32 102
**) with head harness ADVANTAGE,
Si (silicone neck strap)
100 42 663
9
5
Intervals (as required in Germany)
The maintenance intervals are recommended by
MSA AUER. Applicable national regulations must
be observed. If required, the local conditions
during use must be considered for the work to be
performed. In case of doubt, the local MSA repre-
sentative should be consulted and the applicable
national regulations be checked.
Work to
Intervals
be
Before After
Semi-
Two
Four
Six
performed
Use Use
annu-
Years
Years
Years
1)
ally
Cleaning
and
X
X
Disinfection
Visual-,
Function-
and
X
X
X2)
Leak Test
Exhalation
Valve disc
replace-
X
ment
Speech
diaphragm
replace-
X
ment
Check by
user
X
(Tightness)
Summary of Contents for Advantage 3200
Page 32: ...30...
Page 33: ...31 1 2 3 4...
Page 34: ...32...
Page 35: ...33 6 5...
Page 36: ...34...
Page 37: ...35...
Page 38: ...36...
Page 39: ...37 1 2 3 4...
Page 40: ...38 6 5...
Page 41: ...39...
Page 43: ...BG 41 2 2 1 2 2 2 3 T 1 2 3 2 4 4 2 5 3 4 2 3 1 1 2 3 4...
Page 59: ...57 RU 2 2 1 2 2 2 3 1 2 3 2 4 4 2 5 3 Sect 4 2 3 1 1 2 3 4...
Page 61: ...59 RU 5 MSA AUER MSA 1 X X X X X2 X X X 1 2 2001 2001 6 2 6 1 6 2...
Page 68: ...66 UA 2 2 1 2 2 2 3 1 2 3 2 4 4 2 5 3 4 2 1 2 3 4...
Page 70: ...68 UA 5 MSA AUER MSA 1 X X X X X2 X X X 1 2 2001 2001 6 2 6 1 6 2...
Page 73: ...71 KZ 2 2 1 2 2 2 3 1 2 3 2 4 4 2 5 3 4 2 1 2 3 4...
Page 75: ...73 KZ 5 MSA AUER MSA 1 X X X X X 2 X X X 1 2 2001 2001 6 2 6 1 6 2...
Page 77: ......
Page 78: ......
Page 79: ......