Configuring the LX-4000 Series for the First Time
28
MRV Communications, Inc.
www.mrv.com
451-0308
Manually Setting the IP Address Via the CLI
If the unit boots up with or without an IP address from the network, you can change the addressing
via the CLI.
Use the following procedure to change the IP address information as needed:
1. Connect the terminal to the DIAG port (port 0 - port values are 9600 bps, eight data bits, one stop
bit, no parity, and Xon/Xoff flow control).
2. Press <Enter> several times to display the
Login:
prompt.
3. Enter your login name. The default is
InReach
.
4. Enter your password. The default is
access
. The
InReach:0>
user prompt appears.
5. Enter
enable
and press <Enter>. The
Password:
prompt appears.
6. Enter the default
system
and press <Enter>. The
InReach:0>>
superuser prompt appears.
7. Enter
config
and press <Enter>. The
Config:0>>
prompt appears.
8. Enter
interface 1
and press <Enter>. The
Intf 1-1:0>>
prompt appears.
9. Enter
address
ip_address
mask
network_mask
and press <Enter>. The
Intf 1-1:0>>
prompt reappears.
10. Enter
broadcast
broadcast_address
and press <Enter>. The
Intf 1-1:0>>
prompt reap-
pears.
11. Enter
exit
and press <Enter>. The
Config:0>>
prompt appears.
12. Enter
gateway
gateway_address
and press <Enter>. The
Config:0>>
prompt reappears.
13. Enter
exit
and press <Enter>. The
InReach:0>>
superuser prompt appears.
14. Enter
save config flash
to save your changes.
Accessing and Configuring the Graphical User Interface (GUI)
This section describes how to access and configure the LX via the GUI. To perform this procedure,
you need a PC with Java Runtime Environment (JRE) 1.4.2 or later installed.
NOTE:
For optimum GUI performance, MRV recommends that your PC run at 500 MHz or better.
The minimum requirement for desktop color settings is 256.
IMPORTANT
If your browser is connected to an LX running an older software version, you must close
the browser completely and clear the cache before connecting your browser to an LX running a
more recent software version. This is because the Java saves the applet to your PC. If you fail to
close the browser completely, the browser will use the old applet when you connect to the
LX running a later software version, and therefore some features will be missing from the GUI
windows.