Troubleshooting
4-2
MTX5000
User and Technical Manual
Figure 4-4: Summary Alarm Dialog Box - Typical
In all cases, the error message will uniquely identify the problem,
i.e.,
+5.5V Powersupply Error
.
To isolate possible IDU problems, see
“Perform IDU Diagnostics”
on page 3-56
.
See Table 4-1
for a list of Indoor Unit (IDU) error messages and
what to do when they appear.
Table 4-1: IDU Error Messages
Error Message
Error Type
Suggested Technical
Staff Action
+5.5V Powersupply
Error
Major
•
Indicates internal
power supply failure
and potential unstable
operation. Verify IDU
input power.
•
Call MRC Technical
Support.
+12V Powersupply
Error
O K
S um m ary A larm
xxxxxxxxxxxxxxxxx
+24V Powersupply
Error
Minor
•
Indicates minor
internal power supply
failure. Verify IDU
input power.
•
Call MRC Technical
Support.
-12V Powersupply Error
Ext IF Level Too High
Minor
•
Indicates external IF
level is above
recommended level.
Attenuate or
disconnect signal to
avoid system
damage.
•
Call MRC Technical
Support.
FMT Fault Alarm
Major
•
Indicates internal
hardware fault.
•
Call MRC Technical
Support.
Audio1 Unlocked
Minor
Verify audio input is
connected
Audio2 Unlocked
Audio3 Unlocked
Audio4 Unlocked
Analog Video Unlocked
Minor
Verify composite video
input is connected.
Table 4-1: IDU Error Messages
Error Message
Error Type
Suggested Technical
Staff Action
Summary of Contents for MTX5000
Page 1: ...MTX5000 Manual Part No 400591 1 Rev A June 2009 User and Technical Manual Transmitter System...
Page 2: ......
Page 8: ...NOTE TO USER vi MTX5000 User and Technical Manual...
Page 9: ...NOTE TO USER vii MTX5000 User and Technical Manual...
Page 10: ...NOTE TO USER viii MTX5000 User and Technical Manual...
Page 16: ...Notices Notices vi MTX5000 User and Technical Manual...
Page 34: ...Product Description 2 12 MTX5000 User and Technical Manual...
Page 120: ...Routine Operation 3 86 MTX5000 User and Technical Manual...