background image

    

 

4. 

Quick Start Reference 

4.1 Battery Setting 

Insert  and  move  in  the  lithium  battery  as  indicated  direction,  user  can 
easily insert and move the battery.   
 

 

Battery Installation 

 

 

Battery Removal 

 

4.2 Quick Operations 

 

Insert the battery correctly. 

 

Long  press  Power  button  until  the  LED  light  is  on,  and  wait  until 
system finishes initialization.   

 

Slide IR Lens lid down, point to target, and adjust focus to get crisp 
thermal image.   

 

Long press the 

  button to rectify thermal image.   

 

Summary of Contents for IR-CAM-B-70

Page 1: ...tion Manual for Infrared Cameras IR CAM B 70 I 75 B 90 I 95 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION 3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC VER 01...

Page 2: ...red Camera Please read this user manual carefully before first use Also please keep in a safe place for reference in the future Please operate with the recommended instructions in user manual We reser...

Page 3: ...OC and 60OC The device must be kept in original packing case during transport Typical storage place is cool dry ventilated and without strong electromagnetic field Keep the lens surface off grease or...

Page 4: ...View 8 4 Quick Start Reference 9 4 1 Battery Setting 9 4 2 Quick Operations 9 4 3 Measure Target Temperature 10 4 4 Infrared Image and Voice Annotation 10 4 5 Infrared Image Playback 10 4 6 Telephoto...

Page 5: ...Isotherm Color 27 Isotherm Temp 27 Hot Superposition 28 Thermal Superposition Attribute 29 Fusion 30 Alarm Color 33 Analysis Setup 33 Temp Range 34 IR Lens 34 Ambient Temp 34 Reference 35 Ref Temp 35...

Page 6: ...iii Power Save 37 Storage Medium 37 Time Date 38 Factory Default 38 System Information 40 Disc Information 40 6 Building Thermal Imaging Summary 41 7 Technical Specifications 43 8 Technical Support 45...

Page 7: ...iv...

Page 8: ...of electrical wire and equipment detect power leak and prevent system malfunction Petrochemical Industry oil pipeline check material interface detect heat leakage insulation structure and power equipm...

Page 9: ...tem List Wide angle lens Telephoto lens 2 Battery and Charger It is recommended to charge battery immediately when device indicates low power please read more about battery installation and removal me...

Page 10: ...The indicator indicates orange in charging and remains green when fully charged 2 3 Attention for Using Battery Charger Battery Charging can only be conducted inside of a house Do not short circuit th...

Page 11: ...orange indicating the battery is being charged now 2 HotKey button 1 Press to automatically focus and Long press to turn on off LED light 3 HotKey button 2 Press to switch between measured objects po...

Page 12: ...he same direction Select the measure line and sampling line press Up Down Left and Right button to move the line in the same direction Select area box in move menu press Up Down Left and Right buttons...

Page 13: ...this button to manually rectify measurement result LCD screen will display the word rectifying 4 In image viewing mode long press this button to exit After auto rectifying if device has abnormal noise...

Page 14: ...ble It can be connected to headphones to listen the playback audio notes as analog audio output interface It can be connected to the monitor to play videos as a video output interface 16 SD card inter...

Page 15: ...8 3 3 Bottom View 18 External DC In External DC requirement is DC 5V 19 Screw nut on tripod Size of screw nut on tripod 1 4 _20 3 4 Left Side View 20 3 2 Color 270 tiltable LCD...

Page 16: ...nd move the battery Battery Installation Battery Removal 4 2 Quick Operations Insert the battery correctly Long press Power button until the LED light is on and wait until system finishes initializati...

Page 17: ...e and Voice Annotation Each thermal image can save up to 40 seconds voice annotation data Image and voice annotation can later be reviewed on PC by bundled IRSee software To save infrared image press...

Page 18: ...d Wide angle lens The device can be equipped with telephoto lens or wide angle lens Put lens in accord with the dots Figure 1 in line then turn lens in clockwise direction till to the two dots in line...

Page 19: ...ltifunctional interface for audio output or video output connect Monitor to Converter cable using Video cable Enter Setup System Setup Display Device Press the Left or Right to switch to Monitor in th...

Page 20: ...he area to achieve Auto focusing effect 4 Horizontal measuring line Horizontal sampling line Enter the Main Menu Measure Line to select the function 5 Temperature distribution curve sample temperature...

Page 21: ...ge medium IN indicates built in FLASH SD means SD card enter the Main menu Setup System Setup Storage Medium to adjust the storage medium 14 USB symbol USB0 means file transmission USB1 means video tr...

Page 22: ...instead of enter main menu triggers manual rectify Main Menu Using or button to select menu item and selected item is highlighted with white background Press Enter or button to enter sub menu press bu...

Page 23: ...ew thermal image add or edit voice annotation or delete thermal image File Manage Folder is automatically created if not exist when saving thermal image Folder name is MYYMMDD and YYMMDD is year month...

Page 24: ...iew thermal image or press Enter key to delete it and press Exit to exit File Manage window Thermal Image preview Save Save real time thermal image The operation method is the same as Shutter button R...

Page 25: ...y to exit the preview mode Format Format the built in FLASH or SD card When Press Enter button to Main Menu Setup System Setup Storage Medium to select the Internal then format the built in FLASH to s...

Page 26: ...ensure that the data has been transferred to PC before format If the system fails to save images please search and kill viruses and if no virus is found please backup data before formatting 5 2 2 Meas...

Page 27: ...reading at location marked with Up to 4 spots can be selected Spot Measure Attribute Press Hotkey button 2 until spot marker is flashing in yellow and then press Up Down Left and Right buttons to move...

Page 28: ...al Horizontal Line Measure Horizontal Line Measure Horizontal line is temperature sampling line and upper right LCD corner displays temperature measurement reading on vertical cursor line intersection...

Page 29: ...plays temperature measurement reading on horizontal cursor line intersection After using HotKey button 2 select line measure press and button to adjust sampling line position and press and button to a...

Page 30: ...ribute Area Rect Measure Press and button to select or deselect Selected Area is check marked Up to 3 areas can be selected Area Rect Target Selection Area Rect Measure Measure result on upper right L...

Page 31: ...emissivity set reference measure type move size Area Rect Measure Attribute Emissivity Refer to Appendix Emissivity of raw materials Set Reference Set current area as reference If selected all measure...

Page 32: ...This value can be omitted if target is close to device less than 10m Otherwise set Humidity value according to environmental condition Press or once to change Humidity 1 Long press or will change Hum...

Page 33: ...will change this value in 1 interval Save Setting All parameter changes must be saved before power off device Otherwise changes will not be saved for next power on 5 2 3 Image There are 5 items Image...

Page 34: ...tch is on Alarm Temp is the desired alarm temperature Press or once to change Alarm Temp 0 1 Long press or will change Alarm Temp in 1 interval Default setting is 37 0 Alarm Color Alarm Color can sele...

Page 35: ...alyze infrared image There are 3 modes to setup target area to infrared image the other area to visual image Press or button to select Above Below Interval of thermal superposition Interval If select...

Page 36: ...mage overlays visual image below specified temperature Thermal Superposition Attribute In Superpose mode Press Hotkey button 2 the interval area is flashing in yellow then press Enter button to pop up...

Page 37: ...30 Thermal Superposition Attribute Fusion Scaling infrared image overlaying visual image the fusion has 4 types automatic 1 2 Fusion 1 4 Fusion and 3 4 Fusion automatic...

Page 38: ...31 1 2 fusion 1 4 fusion 3 4 fusion...

Page 39: ...onds with no operation system will exit to real time Infrared view screen Fusion Attribute Mixing proportion press or to set Auto 1 2 1 4 3 4 mode Adjust select Size to confirm press buttons to adjust...

Page 40: ...s the preset temperature device will alarm with setting alarm color Alarm Color Alarm Color can select as Auto Black White Red Orange Yellow Green Blue Gray and Purple Default setting is Auto which is...

Page 41: ...e are 3 options 21 5mm standard lens 11mm wide angle lens and 40mm telephoto lens Press or button to select correct IR lens for best measurement result after installing optional IR lens for example if...

Page 42: ...s Enter button to reverse palette for thermal image display Press Enter again to switch back Clear Screen Press Enter button to clear all items at thermal image area L S Auto Manual Mode Press Enter b...

Page 43: ...e options Simplified Chinese Traditional Chinese English Korean Japanese German French Russian Italian Portuguese and Spanish Auto Rectify Set the number of seconds to perform next auto rectify Set va...

Page 44: ...press or button to switch options If select File transmission device is used as a U disk to export delete or format the data saved on the built in FLASH or SD card to PC If select Video device is use...

Page 45: ...me Date Set system date and time Press or button to select an item press or button to change its value and press Enter button to confirm If Li Ion battery is removed for a long time it is necessary to...

Page 46: ...mperature 0 0 O C Alarm Disenabled Alarm temperature 37 0 O C Alarm color isothermal color etc Auto Isothermal temperature 37 0 O C Isothermal height 1 0 O C Thermal superposition type Interval Fusion...

Page 47: ...o close None USB File transmission mode System Settings storage media Flash Time Settings Time No change System Information Select to display system information such as serial number software version...

Page 48: ...s known higher demands are being set on buildings The features of our TI series IR camera make it possible to detect slight temperature difference and to analyze indoor humidity and leakage Hereinafte...

Page 49: ...42 The effect drawing of indoor pipe heat leakage The effect drawing of indoor corner air leakage...

Page 50: ...inuous stepping zoom within 1 4 multiples Digital Zoom 390 395 0 1 continuous stepping zoom within 1 8 multiples Spectral Range 8 14 m visible camera 2Mpixel Image Quality spotlight YES display 3 5 Co...

Page 51: ...temperature input Measure Dew point alarm Available only for 170 and 390 175 Up to over 700 images Storage Media Built in Memory 395 Up to over 500 images 175 Up to over 5600 images 2G Micro SD 395 U...

Page 52: ...nt Problem Cause and Solution Camera cannot be powered on No battery or batteries are not installed correctly Install battery correctly Battery power is used up Change battery or recharge Save power m...

Page 53: ...automatically The battery runs out Replace the battery Battery power runs out fast Ambient temperature is too low or too high The rechargeable battery is not fully charged Recharge the rechargeable b...

Page 54: ...00 0 64 Cast Iron inoxidized 100 0 21 Rough 25 0 94 Wrought Iron Polished 38 0 28 Nickel Oxidized 200 0 37 Stainless Steel Oxidized 60 0 85 Steel 800 Oxidized 200 0 79 Brick 20 0 93 Concrete 20 0 92 G...

Page 55: ...1 Uncooled Focal Plane Infrared Cameras IRSee Report Software User Manual...

Page 56: ...tallation 1 4 Uninstall Software 3 5 Start Software 3 Function Description 5 1 Image Import and Export 5 1 1 Image Import 5 1 2 Image Export 5 2 Modules 6 2 1 Quick Access Toolbar 6 2 2 Ribbon 7 2 3 M...

Page 57: ...ight to edit this manual without further notice 2 Quality Assurance The quality administration system of this product during the process of R D and production has been approved in accordance with ISO9...

Page 58: ...memory 20G or bigger hard disk 1440 900 or higher resolution screen 2 2 Operating System IRSee Software is compatible with Microsoft Windows 2000 XP Vista Windows 7 It provides a multi language versio...

Page 59: ...lease adjust or change as needed Step C Click the Next button continuously until the software installation is completed The system will enter the encoder installation automatically Step D Click and fo...

Page 60: ...ete button if want to reinstall the software 5 Starting up Software The following icon appears on Windows desktop after installing IRSee software Double click the icon and startup IRSee interface Open...

Page 61: ...lified traditional English Italian Japanese Russian French German Korean Spanish and Portuguese IRSee software has auto recognition language function with the operating system in PC the IRSee will be...

Page 62: ...mage Export It is available to export in accordance with the following methods after importing images Method 1 Click the Save As button on the software icon on the upper left corner to pop up a file s...

Page 63: ...the Quick Access Toolbar to customize the buttons in the Ribbon and the file system the buttons function is consistent with the buttons shown in corresponding areas 2 1 1 Customizing the Quick Access...

Page 64: ...ton to save the settings 2 1 3 Position Adjustment of Quick Access Toolbar Right click the Ribbon to pop up a menu Left click the Ribbon Quick Access Toolbar Below and adjust its position 2 2 Ribbon T...

Page 65: ...ter key to confirm it Method 2 Click the Up and Down keys in the edit box to adjust and set an emissivity value 2 2 2 2 Humidity Adjustment Please input a required humidity value 1 100 in the humidity...

Page 66: ...y Operate the option to play back the audio saved in images 2 2 4 Set Temperature Type This option is used to set the temperature display unit click or K to set the temperature unit to Celsius Fahrenh...

Page 67: ...10 Click Next to select an image or multiple images Fill in related information in accordance with different types of report templates Preview...

Page 68: ...11...

Page 69: ...12...

Page 70: ...13...

Page 71: ...14...

Page 72: ...em will prompt whether to save the report or not Click the OK button Input and select the saving path and file name and then click the Save button Click the report in Ribbon Edit Report Select a saved...

Page 73: ...nnect a device set to USB Direct Trans mode for the device Click the device iron on PC software interface Open the device Play 2 2 6 2 Video Click the device Record Select a video path Input the name...

Page 74: ...and name it by a time format 2 2 7 Panel It is mainly used for showing hiding each area a user can adjust the size and position of each display area as needed and then click the Save Settings to save...

Page 75: ...m can operate in accordance with the above prioritization e g if both a point object and a line object are simultaneously selected the point is more prior than line the point object will be prior sele...

Page 76: ...the thermal image to be analyzed Left hold and drag the mouse to the terminal point of the line Vertical Line Click the Create button to pop up a menu Click the Vertical Line button Set the vertical c...

Page 77: ...n the state of mouse becomes left click to select the line Move the mouse to the position of starting point terminal point to be moved When the state of mouse becomes left click to select starting poi...

Page 78: ...d When the state of mouse becomes click to select it Move the mouse to the eight vertexes of the rectangle When the state of mouse becomes click to select it Move the mouse to change the size of the r...

Page 79: ...fied When the state of mouse becomes click to select it Move the mouse to a vertex to be modified When the state of mouse becomes click to select it Move the mouse to change the position of the vertex...

Page 80: ...mouse becomes click to select it Move the mouse to change the size of the ellipse Delete an ellipse Select the ellipse to be deleted Click the button to delete the current temperature measurement obje...

Page 81: ...whole thermal image to TXT file the temperature unit is Celsius 2 3 9 Audio The option is an audio option under Temperature image module the selected iron indicates the image consists of playable aud...

Page 82: ...enabled it is available to draw grid dashed lines on the histogram background if disenabled it s unavailable to draw it is available to click the button to switch 2 4 4 Save a Histogram Click the Sav...

Page 83: ...the background color button to pop up color selection dialog box Select a background color Click the OK button to confirm the background color 2 5 3 Save the line profile measurement image Click the b...

Page 84: ...dew point temperature will be unified 2 6 1 Default maximum or minimum temperature and upper and lower limits of isothermal color Click the button to reload default settings 2 6 2 Adjust upper and lo...

Page 85: ...lect a dew point When a dew point is selected all points which temperature is below the dew point will be colored in uniform 2 6 5 Set isothermal color and dew point color The default isothermal color...

Page 86: ...ect Select a measured object in the label list Add Remarks in the Remarks edit box 0 512 characters available Click the Upload Current Settings button to add remarks 2 7 3 Change emissivity of measure...

Page 87: ...or any image that without visible light Click the Open button to pop up the file selection dialog box Select a file to be added from the dialog box 2 8 2 Save an image Click the Save button to pop up...

Page 88: ...rently added visible image 2 8 4 Flip an image This feature is available for any image that without visible light Click the or button to flip an image clockwise or counterclockwise 2 8 5 Fusion This f...

Page 89: ...infrared image and visible image Set infrared display range Drag the right two progress bars to adjust the infrared display range of interval or above upper or below lower limit Click the OK button t...

Reviews: