Measurement
WATT, VA, Whr,, Power factor, ACV, ACA,
DCV, DCA, Hz, ohm.
Zero Adjustment
Watt :
Watt : External adjustment by push button.
DCV, ACV, DCA, ACA :
Automatic adjustment.
Polarity Automatic
switching, "-" indicates reverse
polarity.
Current input
Direct input, inductive clamp probe or CT.
mode
Over input
Indication of " - - - - or " - - - - .
Indication
Data Output
RS232 serial interface.
Sampling Time
W, VA, ACA, ACV, PF, Hz :
Approx. 1.5 Sec.
DCV, DCA, OHM :
Approx. 1 Sec.
Operating Temp. 0 to 50 ( 32 to 122 ).
Operating
Less than 80 % R.H..
Humidity
Power Supply
Battery power :
DC 9V, 1.5 V AA (UM-3) battery x 6 PCs.
AC power :
AC to DC 9V adapter ( 500 mA ), optional.
Power
Battery power :
Consumption
Approx. DC 30 mA
Dimension
280 x 210 x 90 mm ( 11.0 x 8.3 x 3.5 inch ).
Weight
Approx. 1.6 Kg ( 3.52 LB ).
Standard
Test lead ( red & black ).............. 1 pair.
Accessories
Instruction Manual...................... 1 PC.
2