Pump fragrance delivery too much
or too little
The AromaFlo system has been factory
set to deliver a suitable amount of aromatic fragrance
into a typical sized steam room. Please contact the
MrSteam Technical Service Department before
changing this setting. See page 12 for instructions
on adjusting the amount of fragrance delivery.
Contact the MrSteam Technical Service Dept. at (800)
76-STEAM (East coast) or (800) 72-STEAM (West Coast)
for assistance or additional information.
ELECTRICAL SHOCK HAZARD.
MrSteam
AromaFlo pumps are connected to 120V line voltage
and contain live electrical components. All installation
and service to be performed by qualified and licensed
electricians and plumbers only. Installation or service
by unqualified persons or failure to use MrSteam parts
may result in property damage or in a hazardous
condition.
TROUBLESHOOTING
Ê
/"Ê6"Ê/,Ê-"]Ê-"
-
NECT POWER TO PUMP BEFORE SERVICING
Pump does not prime
1. Check if voltage is available.
2. Check liquid level in fragrance container.
Replenish liquid, if necessary.
3. Check for air bubbles in the suction tube or
the pump head. To eliminate air bubbles see:
Priming Pump.
4. Check valves for contamination. Clean valves
if necessary.
5. Check foot valve in container for contamination.
Rinse foot valve under clean water.
Pump does not inject fragrance into
steam room
1. Check if voltage is available.
2. Check liquid level in fragrance container. Replenish
fragrance if necessary.
3. Check for air bubbles in the suction tube or the
pump head. To eliminate air bubbles see:
Priming Pump.
4. Check valves for contamination. Clean valves if
necessary.
5. Check foot valve in container for contamination.
Rinse foot valve under clean water.
6. Check the pressure tube for kinking or jamming.
Straighten or replace.
7. Check if fragrance is freely flowing through the
Check Valve when the metering pump is energized.
Apply compressed air through the Check Valve.
Attach the compressed air at the point of connection
of the pressure tube.
8. Ensure the pump has been powered up. See page 12.
WARNING
!
WARNING
!
WARNING
!
12
I N S T A L L E R S E C T I O N
AromaFlo
Operation and Installation Instructions
®
All Drawings for Illustrative Purposes Only