L__Y-01 SERIES

    TPI CORPORATION
          PO BOX 4973
JOHNSON  CITY, TN 37602

INSTALLATION INSTRUCTIONS

APPLICATION

The L series are designed for use as operating or regulating controls only. Where control failure could result
in personal injury or the loss of property, an approved backup temperature limit control or an advisory alarm system
should be used to warn of control failure.

Model

Description

Operation

L__Y-01

Heat or Cool SPDT

Opens N.C. circuit on temp. rise/closes N.O. circuit on temp rise.

Electrical Ratings
25 AMP @ 125/240/480 Vac
3/4 HP @ 125 Vac
1 1/2 HP @ 240 Vac

*CAUTION*

Installation must be performed by an experienced, qualified service person.
Always disconnect power supply before performing any work.
Wire nut or otherwise insulate any unused conductors.
All wiring must conform to state and local codes.

Safety Information

1. Disconnect all power before installing or servicing.
2. Be certain that the electrical load that is to be controled does not exceed the thermostat rating.
3. This thermostat is intended for permanent installation and must be installed in accordance with the National
    Elecric Code (NEC) and all state and local codes.
4. Use copper conductors only.

Installation

1. Locate the thermostat sensing bulb 4 to 6 FT. above the floor, where it will be exposed to an average temperature
    of the controlled space. Do not mount near windows, doors or direct sunlight.
2. Remove the thermostat cover. Position the box with the wiring hole oriented as desired. Fasten the box to the wall
    with 2-3 screws through the mounting holes.
3. The thermostat may be installed using conduit, flexible cable or other code approved wiring methods. All fittings
    and materials used should be approved for the application and should be installed in accordance with instructions.
4. Complete the wiring by attaching the thermostat leads in accordance to the applicable wiring diagram using wire
    nuts (not provided). A green groung wire is provided to attach the line and equipment groung to the thermostat.
    After the connections are made, all wires should be pushed back into the box.
5. The thermostat cover should now be attached to the box using the screw provided.

Operation

After installation and wiring, check the operation in the following manner:
1. Adjust the thermostat set point to about 10 degrees below room temperature.
2. Restore power.
3. Slowly raise the set point of the thermostat. When the set point reaches room temperature, the heater should come
    on.

Since the thermostat may be afffected by the installers hand, allow the necessary amount of time after handling before
performing operation check.

The L Series thermostats are factory calibrated and require no field adjustments. Changing the calibration will void the
warranty. Do not bend or damage the sensing bulb as this will afffect operation of the unit.

FORM 8051 REV. A

Summary of Contents for TE8001

Page 1: ...ount directly to a wall use holes located in top and bottom of case Pull wires through hole in center of case Do not depend upon the thermostat as the sole means of disconnecting power when installing...

Page 2: ...the middle and lower two pins TH This activates the fan whenever the thermostat turns the cooling on For an electric heat system place the jumper on the middle and upper pins H C which will allow the...

Page 3: ...ator appears 5 LCD Pattern Description a 2 Large digits for room temperature readout b 4 small bars for 0 2 0 4 0 6 0 8 degree indication c SET TEMP indicator for control temperature setting indicatio...

Page 4: ...limitations on how long an implied warranty lasts The above exclusions or limitations may not apply to you During the warranty period TPI Corporation will at its sole option repair or replace any def...

Page 5: ......

Page 6: ...nstalled in the horizontal position the adjustment lever must extend out the right side of the thermostat If installed in the vertical position the lever must extend out the bottom of the thermsotat 3...

Page 7: ...of the thermostat 6o to 8o F above the room temperature The A C system should turn off The fan may have a delay before it turns off Heating Cooling Model UT8001 1 Turn on power to the heating cooling...

Page 8: ...ing air conditioning and heating ducts Do not install where anything can obstruct free air flow such as drapes or doors 2 Disconnect the power supply to the air conditioning and heating system 3 Gentl...

Page 9: ...ntaining air conditioning and heating ducts Do not install where anything can obstruct free air flow such as drapes or doors 2 Disconnect the power supply to the air conditioning and heating system 3...

Page 10: ...eating ducts Do not install where anything can obstruct free air flow such as drapes or doors 2 Disconnect the power supply to the air conditioning and heating system 3 Gently remove the cover of the...

Page 11: ...y or field installed locking kits for top and for bottom setting and 6 wire leads W W W W WARNING ARNING ARNING ARNING ARNING IF THIS PRODUCT IS USED TO REPLACE A DE VICE CONTAINING MERCURY THE PUR CH...

Page 12: ...t sense the average temperature of the area to be controled Do not mount the thermostat adjacent to water pipes in drafty areas or other locations that would adversely affect the operation of the ther...

Page 13: ...C COOL NC NO C L1 L2 HEAT NC NO C L1 L2 COOL L1 L2 NC NO C L1 NC NO C HEAT L2 COOL CHANGE OVER SWITCH L1 NC NO C HEAT COOL L2 CHANGE OVER SWITCH DIAGRAMS FIG 1 FIG 2 TYPICAL WIRING DIAGRAMS TO BE PRO...

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ...ontrolled space Do not mount near windows doors or direct sunlight 2 Remove the thermostat cover Position the box with the wiring hole oriented as desired Fasten the box to the wall with 2 3 screws th...

Reviews: