PAGE 12 — HTX6H, STX6H TROWEL • SETUP, ADJUSTMENTS AND CALIBRATIONS — REV. #1 (09/07/17)
GENERAL PROCEDURES
SETUP JUMPER INSTALLATION
1. Remove plug (P/N: 42440) from J5 of main harness
(4-pin connector in right rear corner of electrical panel
under the seat).
2. Install Setup Jumper (P/N: 42538 on J5).
NOTICE
These general procedures will be referenced in other
sections throughout the manual.
NOTICE
Machine must be secured prior to installation. Installing
setup jumper will:
• Disable Cold Start
• Increase Engine RPM to Full operating RPM
• Disable Stroke Follower
REMOVE SETUP JUMPER
(If installed).
1. Remove Setup Jumper (P/N: 42538) from J5 of main
harness.
2. Reinstall Plug (P/N: 42440) on J5 of main harness.
Table 2. Disable and Re-enable Options
DISABLE
(If Setup Jumper is not
installed)
Cold Start
1. Open service tool.
2. Click “machine setup” button on main page.
3. Click “Cold Start” button under Setup Menu.
4. Click check box next to Disabled.
5. Press Download Button.
Stroke Follower
1. Open service tool.
2. Click “machine setup” button on main page.
3. Click “Stroke Cont.” button under Setup Menu.
4. Click button “Disable Stroke Follower”.
RE-ENABLE
(If disabled via service
tool)
Cold Start
1. Open service tool.
2. Click “machine setup” button on main page.
3. Click “Cold Start” button under Setup Menu.
4. Uncheck box next to Disable.
5. Press Download Button.
Stroke Follower
1. Open service tool.
2. Click “machine setup” button on main page.
3. Click “Stroke Cont.” button under Setup Menu.
4. Click button “Enable Stroke Follower”.