19
~
113
13hoursafter sunset
~
213
hours before sunrise
114
Load will be on for 14 hours
after sunset
214
Load will be on for 14 hours
before sunrise
115
Load will be on for 15 hours
after sunset
215
Load will be on for 15 hours
before sunrise
116
Test mode
2 n
Disabled
117
Manual mode(Default load
ON)
2 n
Disabled
CAUTION: Please set Light ON/OFF, Test mode and Manual mode via
Timer1. Timer2 will be disabled and display "2 n ".
4.2.2 R485 communication setting
1)
Load working mode
Manual Control (default)
Control ON/OFF of the load via the button or remote commands (e.g., APP or PC
software).
Light ON/OFF
Light ON+ Timer
Time Control
Control the load ON/OFF time through setting the real-time clock.
2) Load working mode settings
(1)PC setting
Connection