17
Over Voltage Reconnect
Voltage
14.7V
12.7V
9
~
17V
Equalize Charging
Voltage
14.5V
12.5V
9
~
17V
Boost Charging Voltage
14.5V
12.5V
9
~
17V
Float Charging Voltage
13.8V
12.2V
9
~
17V
Boost Reconnect
Charging Voltage
13.2V
12.1V
9
~
17V
Low Voltage Reconnect
Voltage
12.8V
10.5V
9
~
17V
Under Voltage Warning
Reconnect Voltage
12.8V
11.0V
9
~
17V
Under Voltage Warning
Voltage
12.0V
10.5V
9
~
17V
Low Voltage Disconnect
Voltage
11.1V
9.3V
9
~
17V
Discharging Limit Voltage
10.6V
9.3V
9
~
17V
The following rules must be observed when modifying the parameter values in
Userforlithium battery.
Ⅰ
.
Over Voltage Disconnect Voltage>Over charging protection voltage(Protection
Circuit Modules(BMS))+0.2V
※
;
Ⅱ
.
Over Voltage Disconnect Voltage>Over Voltage Reconnect Voltage
=
Charging
Limit Voltage ≥ Equalize Charging
Voltage
=
Boost Charging Voltage ≥ Float
Charging Voltage>Boost Reconnect Charging Voltage;
Ⅲ
.
Low Voltage Reconnect Voltage>Low Voltage Disconnect Voltage ≥ Discharging
Limit Voltage;
Ⅳ
.
Under Voltage Warning Reconnect Voltage>Under Voltage Warning Voltage≥
Discharging Limit Voltage;
Ⅴ
.
Boost Reconnect Charging voltage> Low Voltage Reconnect Voltage;
Ⅵ
.
Low Voltage Disconnect Voltage ≥ Over discharging protection voltage
(BMS)+0.2V
※
.
WARNING:
The voltage parameters of lithium battery can be set, but you
must refer to the voltage parameters of lithium battery BMS.
WARNING:
The required accuracy of BMS shall be at least 0.2V. If the
deviation is higher than 0.2V, the manufacturer will assume no liability for
any system malfunction caused by this.
4.1.3 Settings
1)
PC setting
Connection
Summary of Contents for M32-10
Page 35: ...32...
Page 36: ...33 Annex IIMechanicalDimension Diagram M32 10 Unit mm...
Page 37: ...34 M32 20 Unit mm...
Page 38: ...35 M32 30 Unit mm...
Page 39: ...36 M32 40 Unit mm Any changes without prior notice Version number 3 1...