15
07
Auto restart when over
temperature occurs
Restart disable (default)
Restart enable
09
Output frequency
50Hz (default)
60Hz
10
Output voltage
220V
230V (default)
240V
11
Maximum utility charging
current
Note: If setting value in
program 02 is smaller than
that in program in 11, the
inverter will apply charging
current from program 02 for
utility charger.
30A (default)
Setting range is 2A, then from 10A
to 100A. Increment of each click is
10A.
12
Setting voltage point back to
utility source when selecting
“SBU priority” in program 01.
Available options in PIP3624MT model:
23.0V (default)
Setting range is from 22V to
25.5V. Increment of each click is
0.5V.
Available options in PIP5648MT model:
46V (default)
Setting range is from 44V to 51V.
Increment of each click is 1V.
13
Setting voltage point back to
battery mode when selecting
“SBU priority” in program 01.
Available options in PIP3624MT model:
Battery fully charged
27V (default)
Setting range is from 24V to 29V. Increment of each click is 0.5V.
Available options in PIP5648MT model:
Battery fully charged
54V (default)
Setting range is from 48V to 58V. Increment of each click is 1V.
16
Charger source priority:
To configure charger source
priority
If this inverter/charger is working in Line, Standby or Fault mode,
charger source can be programmed as below:
Utility first
Utility will charge battery as first
priority.
Solar energy will charge battery
only when utility power is not
available.