background image

ICM-ETHi

Inline Contamination Monitor
Ethernet Interface

User Guide

200.139-EN

www.mpfiltri.co.uk

Summary of Contents for ICM-ETHi

Page 1: ...ICM ETHi Inline Contamination Monitor Ethernet Interface UserGuide 200 139 EN www mpfiltri co uk ...

Page 2: ... Lantronix software for network configuration The following functions are provided Ethernet to RS485 adaptor using Lantronix drivers DC input socket for ICM power Pre wired ICM connector on 3m flying lead ICM signals brought out to user accessible terminal block This allows external alarms PLCs or a start button to be easily connected LED Indicators indicating Transmit Tx and Receive Rx data Figure ...

Page 3: ...switch Install the Device Installer software from the Software CD or from the following web address http ltxfaq custhelp com app answers detail a_id 644 Navigate to the Device Installer via Program menu Follow menu instructions Identify and record the LAN address used by the device e g 81 187 19 55 Access the Internet explorer enter the LAN address in the navigation bar Press enter Access the Seri...

Page 4: ...avigate to the CPR Manager via Program menu and Open Add a new Com Port Add and Remove Select tick an unused Com Port e g Com 3 and click Ok Configure the Com Port being used double click on COM port Host use value recorded earlier e g 81 187 19 55 TCP Port 10001 Press the Save button menu bar save settings Please Note the following message may appear Figure 1 Click Continue Anyway on all warnings ...

Page 5: ...wn CPR manager and Device installer The new COM port e g COM 3 will now be available in LPA View Install LPA View as per the user guide Open LPA View open remote control 7th button from left on toolbar Choose relevant Com port and click Ok ...

Page 6: ... 0 Accept the security warning and license Figure 1 The CPR Installer The software requires the Microsoft NET Framework If you do not have this already the installer will first install it for you You will then need to restart the computer and run the installer again to install the actual CPR program Follow the installation wizard accepting the defaults You will need to accept another security warni...

Page 7: ...CM ETHi as described above and apply power When the unit is connected correctly you should see a continuous green LED to the left of the RJ45 socket after it has obtained an IP address Run the CPR program Once started press the Search button to search the network for ICM ETHi devices Any such are displayed on the bottom line as in the example below with an appropriate IP address for your network F...

Page 8: ...left hand pane in Figure 3 Then double click the found device shown in the Device List at the bottom of the dialogue Press the Save button to save the configuration Configuration Test Network communications can be tested using the Tests tab as in Figure 4 Press the Open button If successful the dialogue will show Com Status Open Press Close afterwards otherwise the Com port will not be available to...

Page 9: ...Configuration 9 Figure 3 Com Port Settings Figure 4 Testing ...

Page 10: ...the provided DC adaptor The RS485 signals Data Data are also present these may be connected to an existing Modbus network To access the terminal strip remove the four screws holding on the right hand end plate the one with the ICM cable The end plate can then be detached and the top plate slid off An additional cable gland supplied can be fitted in the spare po sition on the end plate and used for c...

Page 11: ...shows how to connect an external start button or PLC output relay Figure 3 External Indicators Figure 3 shows how to connect external indicator lamps in case the built in LED is not sufficient These could also be PLC inputs Figure 4 External Power Supply ...

Page 12: ...permanent installations over the removable plug top power supply that comes with the unit Figure 5 Control Cable Extension The standard cable is 3m in length Wiring over longer distances should be done using twisted pair cabling assuming the serial communications signals are being used Figure 5 shows an example ...

Page 13: ... the right to alter specifications without prior notice Except as permitted by such licence no part of this publication may be reproduced stored in retrieval system or transmitted in any form or any means electronic mechanical recording or otherwise without prior written permission of MP Filtri UK ...

Page 14: ......