Operating Procedures
−
Keep the suction hose as short as possible, make sure the
pressure never drops below atmospheric.
−
Connect the suction line to the lowest point of the reservoir,
e.g. the drain. If this is not possible find a suitable location
or use a down pipe through the filter lid.
−
The point of suction must be below the fluid level.
−
Use correct hydraulic fittings and hydraulic hoses for the in-
stallation.
−
Do not use Teflon tape or liquid sealants.
−
Do not fit ball valve or any other obstructions in the return
line of the filter unit, the return line must be free to flow back
to tank.
−
Keep the return line as short as possible and use hydraulic
hose of the correct internal diameter e.g. 1/4".
−
Make sure the point of return on the reservoir is as far away
as possible from suction point.
4.3 Motor Wiring
Ensure that a qualified electrician carry out the electric installa-
tion of the ACMU.
−
Before installation, ensure that the electrical data of the elec-
tric motor corresponds with the data of the local electrical
supply.
−
Connection 3 phase/ 1 phase