Installation
Electrical Connection
WARNING:
Electrocution may occur when working on ener-
gized circuits. Disconnect power at the main breaker or service
disconnect switch, then lock out and tag it to indicate that work is
being performed on the circuit.
CAUTION:
Electrical connections must be made
AFTER
the plumbing installation.
Damage to the water heaters will occur if the power is turned on without an
adequate water supply.
Follow the instructions below and on the next page to connect power to the machine.
1
Elec. Specs
Rated
Amps
Minimum
Supply
Circuit
Ampacity
Maximum
Overcurrent
Overcurrent
Protective
Device
208/60/1
29
40
40
240/60/1
31
40
40
Elec. Specs
Rated
Amps
Minimum
Supply
Circuit
Ampacity
Maximum
(Breaker Size)
(Breaker Size)
Protective
Device
208/60/1
22
30
30
240/60/1
24
30
30
383HT 40˚F/22˚C Rise Electric Booster (4kW)
383HT 70˚F/39˚C Rise Electric Booster (6kW)
Table - 1
Breaker (Service Disconnect Switch) Size
Fig. 5
CHECK THE ELECTRICAL SPECIFICA-
TIONS ON MACHINE DATA PLATE.
REFER TO THE BREAKER SIZE TABLE
BELOW AND ENSURE THE BUILDING
BREAKER SIZE MATCHES.
REMOVE DISHWASHER LOWER
FRONT PANEL TO ACCESS INTERNAL
COMPONENTS FOR INSTALLATION.
6