![Moyer Diebel 383HT M2 Installation, Operation, Cleaning And Maintenance Manual Download Page 11](http://html1.mh-extra.com/html/moyer-diebel/383ht-m2/383ht-m2_installation-operation-cleaning-and-maintenance-manual_1842796011.webp)
Installation
Water Connection
Continued on the next page.
CAUTION:
To prevent damage to the dishwasher supply valves, the installing
plumber must thoroughly flush debris from the water supply line before connecting
it to the dishwasher. Damage caused by improper installation is not covered by the
limited warranty.
HOT
WATER
Connect the plumbing in accordance with the specifications below.
NOTE:
All plumbing connections
MUST BE POSITIONED
to allow the machine to be
moved for service and cleaning.
INSTALL A 1/2" OR LARGER SHUT-OFF VALVE IN THE WATER SUPPLY
LINE AS CLOSE TO THE DISHWASHER AS POSSIBLE FOR SERVICING.
THE PRV SHIPPED INSIDE THE DISHWASHER
MUST BE INSTALLED
IN THE INCOMING WATER LINE AFTER THE SERVICE SHUT-OFF VALVE.
THE PRV MUST BE ADJUSTED TO PROVIDE 20-22 PSI FLOWING
PRESSURE MEASURED AT THE DISHWASHER.
THE DISHWASHER IS EQUIPPED WITH A 6 FT / 1.8 m FLEXIBLE FILL
HOSE WITH A 3/4" FNPT FITTING.
WATER HARDNESS OF 3 GRAINS/US GAL - 0.83 IMP GAL - 5.3mg/L
OR LESS.
BOOSTER
RISE °F
BOOSTER
kW
MINIMUM INCOMING
TEMPERATURE
MIMIMUM INCOMING
SUPPLY FLOWING PRESSURE
MIMIMUM/MAXIMUM
OPERATING FLOWING PRESSURE
MINIMUM 1/2" NPT OR LARGER HOT WATER SUPPLY LINE.
20-22 PSI 138-152 kPa
45 PSI/310 kPa
45 PSI/310 kPa
110°F/ 43°C
70
°
RISE
6kW
40
°
RISE
4kW
140°F/ 60°C
20-22 PSI 138-152 kPa
3
Summary of Contents for 383HT M2
Page 30: ...Timing Chart 22...
Page 31: ...23 SINGLE PHASE...
Page 33: ...25 Pump Motor 10 12 13 14 9 8 7 6 5 4 3 2 1 11 15...
Page 35: ...27 Booster 1 1 7 3 5 6 8 9 10 11 11 12 4 2 3 3 4 3...
Page 37: ...29 Control Panel 1 3 3 4 7 7 5 5 8 4 2 9 1 1 2 1 3 1 4 1 6 10 0 1 6 1 5 1...
Page 39: ...31 Power Wiring Box 4 12 9 11 3 8 7 6 5 13 1 8 2 10...
Page 41: ...33 Fill Valve 1 5 4 3 2...
Page 47: ...39 Panels and Door 1 2 3 5 4 7 7 8 9 11 12 15 10 6 6 16 17 13 14...
Page 49: ...41 Upper Tank 1 2 3 4 5 6 7 7 17 8 10 14 13 11 12 9 15 16...
Page 51: ...43 2 1 7 11 3 4 6 5 5 7 7 8 9 11 12 8 9 10 13 Tank Rear...
Page 53: ...Chemical Pumps 2 3 6 7 1 4 10 3 4 17 8 9 12 13 15 14 45 11 21 19 18 20 5 15 5...
Page 55: ...47 Dish Racks PRV 1 2 3...
Page 57: ...49 Blank Page This Page Intentionally Left Blank...