6-4
Industio
CI-134 Series User’s Manual
Step 9.
Remove the jumper on position JP1.
jumper
JP1
Remove
Step 10.
Power on the PC.
ON
Windows NT
This section is specific for troubleshooting under Windows NT. For general problems
and solutions, please see the previous section, “General Troubleshooting”.
1. After the system r eboots, the er r or message “Another dr iver in the system,
which did not r epor t its r esour ces, has alr eady claimed the inter r upt used by
xxx.” appear s in the Event Log.
This indicates that the MOXA board is found, but the IRQ is conflicting with
another adapter. Please make sure there is no conflict with other adapter’s IRQ.
Check the BIOS IRQ settings first. Make sure that an IRQ is available.
2. After the system r eboots, the er r or message “Cannot find any configur ed
MOXA Smar tio/Industio Ser ies boar d!” appear s in the Event Log.
a. Some partial decoded network board may interfere with our board. Please
avoid from using 0x300 as I/O address for those network boards.
b. Check hardware configuration of
Industio
CI-134 Series board by IO-
IRQ.EXE. Then make sure the hardware configuration, including I/O
addresses for each port, Interrupt Vector, IRQ, is identical to that of the driver.
c. The I/O addresses may conflict with other devices, please change another set
of I/O address such as I/O:0x280, Interrupt Vector:0x2C0.